User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. HOMELOGIXTM QUICK REFERENCE
- 3. SPECIFICATIONS
- 4. USER MENU STRUCTURE
- 5. INSTALLATION
- 6. PROGRAMMING HOMELOGIXTM
- 7. INSTALLERS MENU
- 7.1 Accessing the Installer Menu
- 7.2 Change Code
- 7.3 Zones
- 7.4 Enrolling
- 7.5 Security
- 7.5.1. Exit Delay
- 7.5.2. Entry Delay
- 7.5.3. Auto Arming
- 7.5.4. Siren Time
- 7.5.5. Siren Mode
- 7.5.6. Relay Polarity
- 7.5.7. Local Siren
- 7.5.8. Supervision Time
- 7.5.9. Jamming
- 7.5.10. No Activity Time
- 7.5.11. Trouble Beeps
- 7.5.12. Bypass
- 7.5.13. Quick Arm
- 7.5.14. Panic Button
- 7.5.15. Duress Code
- 7.5.16. Alarm Cancel
- 7.5.17. Alarm Abort Time
- 7.5.18. Backlight Time
- 7.5.19. Hide Display
- 7.5.20. Key Beeps
- 7.6 Communications
- 7.7 Automation
- 7.8 Messages
- 7.9 Maintenance
- 8. READING THE EVENT LOG
- Annex I. ACCESSORIES
- I.1 HomeLogiXTM Compatible Detectors
- I.1.1. Wireless Passive Infra-Red (Motion) Detector
- I.1.2. Advanced Wireless Spherical PIR (Motion) Detector
- I.1.3. Magnetic Contact Sensor
- I.1.4. Glass Break Detector
- I.1.5. Universal Wire to RF (Two-Channel) Transmitter
- I.1.6. Smoke and Heat Detectors
- I.2 HomeLogiXTM Compatible Remotes
- I.2.1. Wireless 3-Button Remote Control Transmitter
- I.2.2. Wireless Emergency Panic Pendant
- I.2.3. 1, 2 or 4-Button Remote Controls
- I.2.4. HomeLogiXTM Compatible Wireless Siren
- I.2 HomeLogiXTM Compatible Remotes
- I.1 HomeLogiXTM Compatible Detectors
- Annex I. ACCESSORIES
INSTALLERS MENU
HomeLogiX Installer Manual
Page 33
Troubles (enabled by default)
Alerts
Bypass
Arm/disarm
Restore
• CS Secondary specifies the secondary telephone number dialed and the
secondary account code – the number that identifies your system to the
second central station. The events reported are the events specified during
setup. Follow the instructions in CS Primary
• Protocol, specifies the reporting protocol used by the system to report events to
the central stations. Currently only Contact ID is available.
• Dialing Attempts specifies the number of times the system attempt to dial the
primary stations number before attempting to dial the secondary number. Using
the numeric keypad select 1 to 16 attempts, press Enter to save. The system is
set to 3 attempts by default.
7.6.4. Line Test
Enables you to specify the time when the telephone line and CS reporting is tested
and reported to the central station, as well as the number of days between each test
(CS periodical reporting).
To set up line test:
Using the Menu button, select between the two options, and press Enter to confirm:
• Repeats, specifies the number of days between tests. Using the numeric
keypad, choose 1 to 30 days press Enter to save; default is 7.
• Test Time Using the numeric keypad, specifies the time of day (24-hour day
convention) to perform the test by typing the four digits of the desired hour,
press Enter to save. The test time is set at 12:00 by default.
7.6.5. AC Fail Report
This option allows you to specify a delay time, before reporting the power failure to the
CS, in which time power may be restored. The time is set to 0 (disabled) by default.
To set up AC fail report:
Using the numeric keypad, set the time between 1 – 240 minutes, or set it to 0 to
disable the option, press Enter to save.
7.6.6. 2-Way Voice Behavior
The HomeLogix panel enables the CMS operator to open a 2-Way Voice session with
the panel. The only events used in 2-way voice are: TAMPER, EMERGENCY, and
ALARM/RESTORE.
In general, 2-Way Voice Behavior option is achieved via simplex telephone
communication. The CMS operator can listen, talk, or close communication by