User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. HOMELOGIXTM QUICK REFERENCE
- 3. SPECIFICATIONS
- 4. USER MENU STRUCTURE
- 5. INSTALLATION
- 6. PROGRAMMING HOMELOGIXTM
- 7. INSTALLERS MENU
- 7.1 Accessing the Installer Menu
- 7.2 Change Code
- 7.3 Zones
- 7.4 Enrolling
- 7.5 Security
- 7.5.1. Exit Delay
- 7.5.2. Entry Delay
- 7.5.3. Auto Arming
- 7.5.4. Siren Time
- 7.5.5. Siren Mode
- 7.5.6. Relay Polarity
- 7.5.7. Local Siren
- 7.5.8. Supervision Time
- 7.5.9. Jamming
- 7.5.10. No Activity Time
- 7.5.11. Trouble Beeps
- 7.5.12. Bypass
- 7.5.13. Quick Arm
- 7.5.14. Panic Button
- 7.5.15. Duress Code
- 7.5.16. Alarm Cancel
- 7.5.17. Alarm Abort Time
- 7.5.18. Backlight Time
- 7.5.19. Hide Display
- 7.5.20. Key Beeps
- 7.6 Communications
- 7.7 Automation
- 7.8 Messages
- 7.9 Maintenance
- 8. READING THE EVENT LOG
- Annex I. ACCESSORIES
- I.1 HomeLogiXTM Compatible Detectors
- I.1.1. Wireless Passive Infra-Red (Motion) Detector
- I.1.2. Advanced Wireless Spherical PIR (Motion) Detector
- I.1.3. Magnetic Contact Sensor
- I.1.4. Glass Break Detector
- I.1.5. Universal Wire to RF (Two-Channel) Transmitter
- I.1.6. Smoke and Heat Detectors
- I.2 HomeLogiXTM Compatible Remotes
- I.2.1. Wireless 3-Button Remote Control Transmitter
- I.2.2. Wireless Emergency Panic Pendant
- I.2.3. 1, 2 or 4-Button Remote Controls
- I.2.4. HomeLogiXTM Compatible Wireless Siren
- I.2 HomeLogiXTM Compatible Remotes
- I.1 HomeLogiXTM Compatible Detectors
- Annex I. ACCESSORIES
INSTALLERS MENU
HomeLogiX Installer Manual Page 32
• Report Options specifies the event groups that are included in a report. Using
the Menu button, Enable or Disable a group, as required and press Enter to
confirm:
o Alarms (enabled by default)
o Troubles (enabled by default)
o Alerts
o Bypass
o Arm/disarm
o Restore
• Dialing Attempts specifies the number of times the system attempts to dial a
private number before dialing the next specified private number. Using the
Menu button, specify between 1, 2, 3, 4, or 5 dialing attempts press Enter to
save. The default is 3 attempts.
7.6.3. CS Report Setup
This menu enables you to set up the Central Station (CS) report options:
To set up CS report:
Follow these steps:
• CS Report method specifies the reporting method. Using the Menu button,
select one of the following and press Enter to confirm:
o Primary Only(default)
o Alternate
o Secondary
o Both
o Disable
• CS Primary specifies the first telephone number of the first central station to
which the system reports in case of an event, and the primary account code –
the number that identifies your system to the central station. The events
reported are the events specified during setup.
Follow these steps:
Note:
For PABX use the digit followed by "*" and then the full number
o Phone Number, Using the numeric keypad, enter the CS telephone
number, press Enter to save, Press the pound key (#) to delete an existing
number
o Account Code, Using the numeric keypad, enter a code of four digits
and press Enter to confirm
o Report Options specifies the event groups which are included in a report.
Using the Menu button, Enable or Disable a group, as required and press
Enter to confirm:
Alarms (enabled by default)