User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. HOMELOGIXTM QUICK REFERENCE
- 3. SPECIFICATIONS
- 4. USER MENU STRUCTURE
- 5. INSTALLATION
- 6. PROGRAMMING HOMELOGIXTM
- 7. INSTALLERS MENU
- 7.1 Accessing the Installer Menu
- 7.2 Change Code
- 7.3 Zones
- 7.4 Enrolling
- 7.5 Security
- 7.5.1. Exit Delay
- 7.5.2. Entry Delay
- 7.5.3. Auto Arming
- 7.5.4. Siren Time
- 7.5.5. Siren Mode
- 7.5.6. Relay Polarity
- 7.5.7. Local Siren
- 7.5.8. Supervision Time
- 7.5.9. Jamming
- 7.5.10. No Activity Time
- 7.5.11. Trouble Beeps
- 7.5.12. Bypass
- 7.5.13. Quick Arm
- 7.5.14. Panic Button
- 7.5.15. Duress Code
- 7.5.16. Alarm Cancel
- 7.5.17. Alarm Abort Time
- 7.5.18. Backlight Time
- 7.5.19. Hide Display
- 7.5.20. Key Beeps
- 7.6 Communications
- 7.7 Automation
- 7.8 Messages
- 7.9 Maintenance
- 8. READING THE EVENT LOG
- Annex I. ACCESSORIES
- I.1 HomeLogiXTM Compatible Detectors
- I.1.1. Wireless Passive Infra-Red (Motion) Detector
- I.1.2. Advanced Wireless Spherical PIR (Motion) Detector
- I.1.3. Magnetic Contact Sensor
- I.1.4. Glass Break Detector
- I.1.5. Universal Wire to RF (Two-Channel) Transmitter
- I.1.6. Smoke and Heat Detectors
- I.2 HomeLogiXTM Compatible Remotes
- I.2.1. Wireless 3-Button Remote Control Transmitter
- I.2.2. Wireless Emergency Panic Pendant
- I.2.3. 1, 2 or 4-Button Remote Controls
- I.2.4. HomeLogiXTM Compatible Wireless Siren
- I.2 HomeLogiXTM Compatible Remotes
- I.1 HomeLogiXTM Compatible Detectors
- Annex I. ACCESSORIES
INSTALLERS MENU
HomeLogiX Installer Manual
Page 29
7.5.14. Panic Button
Enables the user to generate an alarm (audible or silent) by pressing the emergency
button on the control panel, the remote control panic button will remain active at all
times if enrolled. The local emergency button is disabled by default.
To set a panic button:
Using the Menu button, select one of the following options and press Enter to confirm:
• Audible: to set an audible panic alarm that transmits a message to the CMS or
private telephone set.
• Silent: to set a silent panic alarm that transmits a message to the CMS or private
telephone set, but without a siren
• Disabled: to disable the panic alarm button all together
7.5.15. Duress Code
The system allows you to define a duress code, which a user can enter when forced to
disarm the system under duress. By default, the duress code option is disabled, and
there is no duress code set.
Note:
The duress code should NOT be identical to any other existing code.
To change the duress code:
Type a new four-digit duress code using the numeric keypad and press Enter to save
your new code.
To disable the duress code:
Press the pound key (#), the code will disappear, and the duress code option will be
disabled, press Enter to save.
7.5.16. Alarm Cancel
Specifies the amount of time during which if the user disarms the alarm, the system
sends a “Cancel Alarm” message to the central station. By default, The Alarm Cancel
is set to 00 minutes (disabled).
To set the Alarm Cancel:
Using the numeric keypad, set the alarm cancel time between 01 – 60 minutes, or set it
to 00 to disable the option.
7.5.17. Alarm Abort Time
The system will sound a warning, but the central station will not receive notification of
the alarm if the user disarms the system within the specified alarm abort time. This
function applies to interior and/or perimeter zones only. The Alarm Abort Time is set to
00 minutes (disabled).