User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. HOMELOGIXTM QUICK REFERENCE
- 3. SPECIFICATIONS
- 4. USER MENU STRUCTURE
- 5. INSTALLATION
- 6. PROGRAMMING HOMELOGIXTM
- 7. INSTALLERS MENU
- 7.1 Accessing the Installer Menu
- 7.2 Change Code
- 7.3 Zones
- 7.4 Enrolling
- 7.5 Security
- 7.5.1. Exit Delay
- 7.5.2. Entry Delay
- 7.5.3. Auto Arming
- 7.5.4. Siren Time
- 7.5.5. Siren Mode
- 7.5.6. Relay Polarity
- 7.5.7. Local Siren
- 7.5.8. Supervision Time
- 7.5.9. Jamming
- 7.5.10. No Activity Time
- 7.5.11. Trouble Beeps
- 7.5.12. Bypass
- 7.5.13. Quick Arm
- 7.5.14. Panic Button
- 7.5.15. Duress Code
- 7.5.16. Alarm Cancel
- 7.5.17. Alarm Abort Time
- 7.5.18. Backlight Time
- 7.5.19. Hide Display
- 7.5.20. Key Beeps
- 7.6 Communications
- 7.7 Automation
- 7.8 Messages
- 7.9 Maintenance
- 8. READING THE EVENT LOG
- Annex I. ACCESSORIES
- I.1 HomeLogiXTM Compatible Detectors
- I.1.1. Wireless Passive Infra-Red (Motion) Detector
- I.1.2. Advanced Wireless Spherical PIR (Motion) Detector
- I.1.3. Magnetic Contact Sensor
- I.1.4. Glass Break Detector
- I.1.5. Universal Wire to RF (Two-Channel) Transmitter
- I.1.6. Smoke and Heat Detectors
- I.2 HomeLogiXTM Compatible Remotes
- I.2.1. Wireless 3-Button Remote Control Transmitter
- I.2.2. Wireless Emergency Panic Pendant
- I.2.3. 1, 2 or 4-Button Remote Controls
- I.2.4. HomeLogiXTM Compatible Wireless Siren
- I.2 HomeLogiXTM Compatible Remotes
- I.1 HomeLogiXTM Compatible Detectors
- Annex I. ACCESSORIES
INSTALLERS MENU
HomeLogiX Installer Manual Page 28
Note:
Required zones should be set to ‘Enabled’ for this security feature to work
7.5.11. Trouble Beeps
Determine whether the system will emit a “trouble beep” indicated by a series of four
short beeps once a minute for the following “Trouble” events:
• Low battery (detectors and system)
• Supervision loss (detectors)
• Power failure (system)
• Communication failure (system)
• Tamper(system and zones)
• RF jamming
The default is set to Enabled
To specify trouble beeps:
• Using the Menu button, choose to Enable or Disable the trouble beeps and
press Enter to confirm
7.5.12. Bypass
Specifies either manual bypassing of individual zones, or enables the system to
forcedly arm open zones when armed. Bypass is turned off by default.
To set bypass:
Using the Menu button, select one of the following options and press Enter to confirm:
• Off to set the bypass off
• Off Force/Manual to set the manual bypass
• Manual/Force to set the forced arming (automatic bypass)
7.5.13. Quick Arm
Enables the user to arm the system without entering a code; Quick Arm is set to
disable by default.
To enable/disable quick arm without a code:
Using the Menu button, select one of the following options and press Enter to confirm:
• Enter Installer menu/Security/Quick Arm/Enable
• Enter Installer menu/Security/Quick Arm/Disable
To utilize quick arm:
• Give a long press on the ESC key.
The panel is armed AWAY or HOME.