User's Manual

Table Of Contents
INSTALLERS MENU
HomeLogiX Installer Manual Page 22
7.4 Enrolling
Change
Code
Zones
ENROLLING Security Communications
Automation
Messages Maintenance
Detectors
Remote
controls
R. Sirens
Keypads
Repeaters
The Third sub menu is ENROLLING. Browse the desired application listed below using
the Menu button and access it by pressing the Enter button:
Detectors
Remote controls
Sirens
Keypads
Repeaters
7.4.1. Detectors
You can enroll up to 39 detectors, one detector per zone, numbered 01 through 39.
Zone no. 40, which is dedicated to a hardwire detector can only be enabled or
disabled under this sub-menu, by default this zone is disabled.
To enroll/delete a detector:
Select the desired zone by either browsing all 39 zones using the Menu button or by
entering the zone number using the numeric keypad.
If no detector is associated to the selected zone, for 30 seconds the screen will show a
message saying “waiting for detector signal” initiate a transmission from the detector
(Alarm, Tamper, or any other transmission available, see the detector’s manual for
reference). When the transmission is detected you will be asked to press the Enter
button to store the detector into the zone.
Note:
When enrolling smoke and heat detectors, select the zone type “fire”.
If no signal is received with the allocated 30 seconds the unit will return to normal
mode.
If the selected zone has a detector associated, you will be asked whether you wish to
delete it. Press Enter to delete the detector or the Quick (ESC) button to go back.