User's Manual

Table Of Contents
SPECIFICATIONS
HomeLogiX Installer Manual Page 10
3. SPECIFICATIONS
3.1 RF Data
RF Unit Type Integrated RF transceiver (two-way) shielded super heterodyne, fixed
frequency
Antenna Type Printed PCB type antenna
Operating
Frequencies
433.92 MHz G series
868.35 MHz H series
Receiver
Sensitivity
Up to -68 dBm
Transmitter
Power
Up to +10 dBm, less based on country requirements
Range
(open field)
Up to 250 m in open space for detectors, and 110 m for hand-held
remote controls
RF Device ID
Coding
three-bytes non-replicated per sensor type, or multiples of 16 million
possible codes, make it almost impossible to have two like coded
transmitters
The HomeLogiX
TM
system has optimum range if installed according to the
manufacturer’s recommendations, though this range may be affected by radio noise
from high-power nearby sources, or interference with the signal (blocking) by large
metal surfaces, or multiple concrete walls.
3.2 Environmental Data
Operation temperature: 0º – 60º C (32º F - 140º F)
Storage temperature: -25 º – 70º C (-13º F - 158º F)
Relative humidity: 85% at 30º C Non condensing
Dimensions: 220mm (L) x 140mm (W) x 48mm (D) (8.7"(L) x 5.5" (W) x 1.9" (D))
Weight: 595gr. (1.3lbs.)
3.3 Electrical Data
Display: 2 Lines of 16 characters, backlit LCD
Two fully programmable PGM open collector outputs, 200mA, PTC protected
External Siren output of 1A relay
Case tamper protection
On-board, supervised wired zone and wired tamper inputs
Local, 87dbA siren
External power supply: 220VAC / 50Hz, 110VAC / 60Hz (15VDC, 800mA)
Current consumption: 250mA (standby), 500mA (max)
Auxiliary power output: 12VDC, 500mA max
Internal backup battery: 800mAh for 2 hours standby, 2 hours full alarm