User's Manual
Table Of Contents
Editing a Panel Account
HomeLogiX Software Manual Page 20
Section Property
Item
Description
Sirens
tes)
Siren Time
(Minu
The number of minutes (0-99) to sound the
sirens in case of an alarm.
Relay Polarity ally Closed.
eneral
ecurity
tings
)
be
triggered. The options are: 1, 2, 4, 6, 8, 16, 24,
.
Sirens Mode The sirens will be activated if the specified
arming mode is set. The options are: Away,
Away + Home.
Wired Siren The polarity of the wired siren. The options are:
Normally Opened, Norm
Internal Siren The status of the internal siren. The options are:
Enabled or disabled.
G
S
Set
Supervision
Time (Hours
If this number of hours elapsed and
HomeLogiX
TM
did not receive any message
from a zone, a zone trouble event will
and 48
Jamming
Detection
Defines the method used to detect attempts to
jam the RF signals from its enrolled detectors.
The options are: Disabled, UL Enabled, and EN
Enabled.
ity If the timer i
ours)
s enabled and there is no activity
for the specified number of hours for any of the
No Activ
Timer (H
(version 2
and up)
zones where no activity check is enabled, a
trouble event is reported. The options are:
Disabled, 1, 2, 5, 10, 15, and 30.
Trouble Beeps
If enabled, beeps are generated during system
trouble. The options are: Enabled or Disabled.
Bypass The method of setting a zone as bypassed. The
: Off, Manual, Force.
Options options are
Quick Arm If enabled, HomeLogiX
TM
may be armed
without entering a user code. The options are:
Enabled or Disabled.
Panic Button If enabled, pressing the panic button will be
reported (with a chime if the Audible value is
selected). The options are: Disabled, Audible,
and Silent.
Duress Code The duress (forced disarm) code - 4 decimal
digits.
Alarm Cancel
Time (Minutes)
During this time window (0-60 minutes), after an
alarm started, a disarm will result in an Alarm
Cancelled message sent to the Central Station.