PROGRAMMING
SP-03V2 Installation Manual
Page 46
3. Use the Up and Down buttons to select the desired log option
and press Enter to confirm.
• History Logs – opens the complete log which includes all
events (alarms, trouble warnings, etc.).
• Event Log – Opens only the alarm event log.
4. To exit the log, press the Cancel button.
5.3.8 Setting Zone Bypass
You can define certain zones to be bypassed when arming the
system to deal with various situations, such as when the sensor
battery is low and sends an event, or when the system is armed while
someone is still on premises. You must determine whether or not to
activate the zone bypass.
Note:
This feature is available to only if the installer
enables it from the installer menu. See Bypass
Option, on page 24.
To Define Bypass Zones:
1. Access the Master menu as explained on page 41.
2. Use the Up and Down buttons to locate the B
YPASS OPTIONS
submenu. Press the Enter button to access the submenu.
3. Set the bypass map – Use the Up and Down buttons to select S
ET
BYPASS MAP.
• Use the Up and Down buttons to select the desired zone (zones
01 through 16) and press Enter.
• Use the Up and Down buttons to select
BYPASS or UNBYPASS, and
press Enter to confirm.
4. Clear the entire bypass map – Use the Up and Down buttons to
select C
LEAR BYPASS MAP – this returns all zones to default bypass
setting. Press Enter to confirm deletion.
5. Set the bypass behavior – Use the Up and Down buttons to select
S
ET ACTIVATION – choose the activation behavior to either Always,
Once, or not at all (Off).