PROGRAMMING
SP-03V2 Installation Manual
Page 26
2. Use the Up and Down buttons to locate the SECURITY submenu.
Press the Enter button to access the submenu.
3. Select E
NABLE INSTANT ARM.
4. Use the Up and Down buttons to choose E
NABLED or DISABLED and
press Enter to confirm.
Emergency Alarm Mode
The emergency alarm mode allows the user to generate an
emergency alarm (audible or silent) by pressing the local
emergency button or the remote panic button.
To Set the Emergency Alarm Mode:
1. Access the Installer menu as explained on page 16.
2. Use the Up and Down buttons to locate the S
ECURITY submenu.
Press the Enter button to access the submenu.
3. Select E
MERGENCY ALARM.
4. Use the Up and Down buttons to select one of the following
options and press Enter to confirm:
• Audible: to set an audible panic alarm that transmits a
message to the CMS or private telephone set.
• Silent: to set a silent panic alarm that transmits a message to
the CMS or private telephone set, but without a siren.
• Disabled: to disable the panic alarm button all together.
Duress Code
The system allows you to define a duress code, which a user can
enter when forced to disarm the system under duress. By default, the
duress code option is disabled, and there is no duress code set.
Note:
The duress code should NOT be identical to any other existing
code.
To Change the Duress Code:
1. Access the Installer menu as explained on page 16.