User's Manual Part 2

Compatibility: The SAK-25 Wire to RF Transmitter, with Magnetic Contact Sensor, is compatible with a variety of
Rosslare's receivers and panels, in 433.92 or 868.35 MHz
- 2 -
Local Programming the operation of the SAK-25 is available locally using the push buttons S1
and S2 and the Tri Color LED.
1) Press both buttons at the same time and release when the LED is solid orange to enter the
menu
2) You will see the current mode of the ID Code settings upon release of both of the buttons.
Mode 1: All channels report independent ID
Mode 2: All channels report same ID
3) Press S2 to toggle the current setting.
Same ID Code for all 3 Inputs
If the mode was independent ID's (Flashing Red),
pressing S2 will toggle the mode to same ID Codes for three Channels.
Press both S1 and S2 together to exit the menu.
Different ID Codes for all 3 Inputs
If the mode was Same ID's (Solid Red),
pressing S2 will toggle the mode to independent ID Codes for three Channels.
Press both S1 and S2 together to exit the menu.
SOLID ORANGE MENU for Programming Channels Common ID and Independent ID Codes.
S2
S2
Solid Red LED
Flashing Red LED
Solid Red LED
Flashing Red LED
Solid Red LED
Flashing Red LED
Solid Orange LED MENU
S2S1
LOCAL PROGRAMMING (cont.)
Local Programming the operation of the SAK-25 is available locally using the push buttons S1
and S2 and the Tri Color LED.
1) Press both buttons at the same time and release when the LED is solid orange to enter the
menu.
2) You will see the current mode of the ID Code settings upon release of both of the buttons.
Mode 1: Built-in Magnetic Sensor will not automatically send restore, only when the magnet
will be effectively restored.
Important Note: This local menu will only allow programming if Input 1 is programmed as
Magnetic Door/ sensor & Normally Open
Mode 2: Built-in magnetic sensor will automatically send the restore signal after two seconds,
even if the magnet has not been effectively restored.
Important Note: This local menu will only allow programming if Input 2 is programmed as 3,6
or 9 pulses rolling shutter or vibration pulse counting.
3) Press S2 to toggle the current setting
Toggling Mode 1 to Mode 2
If the mode was Mode 1 (Flashing Red) pressing S2 will toggle the mode to Mode 2.
Toggling Mode 2 to Mode 1
If the mode was Mode 2 (Flashing Red) pressing S2 will toggle the mode to Mode 1.
FLASHING ORANGE MENU for Programming Channel 3 Local Magnetic Sensor Restore Event Operation
Flashing Orange LED MENU
S2S1
Solid Red LED
Flashing Red LED
S2
S2
Solid Red LED
Flashing Red LED
Solid Red LED
Flashing Red LED
SA-25 Instruction Manual - Version 1.0 (Page 2/4)