User's Manual
Table Of Contents
Technical Specifications
Page 9
SA-80A Installation Manual
4. Technical Specifications
Power Characteristics
Input Voltage: 14-18VDC.
From host panel or wall adapter.
Battery Charging Current: 300 mA max
No alarm
Input Current: 0.6 A; during alarm
Standby: < 100mA; no alarm
Battery Characteristics
Battery Capacity: 2.3 Ahr; 12 V sealed lead-acid
battery
Battery Lifetime: 5 years; typical
Battery Backup: 24 hr min.; in standby mode
Electrical Characteristics
Frequency H model
868.35 MHz; ± 0.1 MHz
Frequency G model
433.92 MHz; ± 0.1 MHz
Effective Transmit Power
10 mW nominal
Transmit Range
>180 m
Receiver Sensitivity
-100 dBm min.; For 100 kHz
bandwidth