User's Manual

Table Of Contents
Default Parameter Values
HLX-24 Hardware Installation and Programming Manual 65
Description Default Value Range
Cross time (seconds) 30 0..90
Abort time Enabled
Security
Exit delay (seconds) 60 45..255
Entry delay (seconds) 30 30..240
Silent exit and entry Disabled
Restart exit Enabled
Auto Arming SundaySaturday
Arm mode Disabled
Arm time 00:00
Arming duration (minutes) 0 0..9999
Sirens
Siren time (minutes) 3 01..15
Siren mode Away + Home
Wired siren relay polarity N.O
Internal siren Enabled
Wired siren Enabled
General Security Settings
Supervision time (hours) 24 1..48
Jamming detection Disabled
No activity timer Disabled
Trouble beeps Disabled
Bypass option Off
Quick arm Disabled
Panic button Audible
Duress code
Alarm cancel time (minutes) 5 0 (disable), 5..10
Alarm abort time (seconds) 30 0..45
Backlight time 15 15, Always
Hide display Off
Key beeps On
Instant arm On
Language English
CP-01 Settings
Recent to close time (minutes) 2 0..15
Swinger shutdown time (hours) 8 0..8
Abort annunciation Enabled
Cancel annunciation Enabled