User's Manual
Table Of Contents
- 1. Introduction
- 2. HLX-24 Quick Reference
- 3. Specifications
- 4. Installation
- 5. Programming the HLX-24
- 6. Installer Menu
- 6.1 Change Code
- 6.2 Zones
- 6.3 Enrolling
- 6.4 Security
- 6.4.1 Exit Delay
- 6.4.2 Exit Restart
- 6.4.3 Entry Delay
- 6.4.4 Auto Arming
- 6.4.5 Siren Time
- 6.4.6 Siren Mode
- 6.4.7 Local Siren
- 6.4.8 External Siren
- 6.4.9 Supervision Time
- 6.4.10 Jamming
- 6.4.11 No Activity Time
- 6.4.12 Trouble Beeps
- 6.4.13 Bypass Option
- 6.4.14 Quick Arm
- 6.4.15 Arm Instant
- 6.4.16 Panic Button
- 6.4.17 Duress Code
- 6.4.18 Alarm Cancel
- 6.4.19 Alarm Abort Time
- 6.4.20 Backlight Time
- 6.4.21 Hide Display
- 6.4.22 Key Beeps
- 6.4.23 Select Language
- 6.4.24 EN-CENELEC
- 6.4.25 CP-01
- 6.5 Communications
- 6.6 Automation
- 6.7 Messages
- 6.8 Maintenance
- 7. User Menu Structure
- 8. Reading the Event Log
- A. Quick Reference to Installer Menu
- B. Quick Reference to User Menu
- C. Sensor Placement and Helpful Reference Tables
- D. Reporting Codes
- E. GSM Stick Errors
- F. Settings Requirements for CENELEC
- G. Default Parameter Values
- H. Labeling Instructions
- I. Declaration of Conformity
- J. Limited Warranty
Reporting Codes
60 HLX-24 Hardware Installation and Programming Manual
D. Reporting Codes
Table 14 provides a listing of the codes used to communicate with the CMS.
Table 14: List of CID Codes
Programmable Feature Description CID Code
Burglary Event (Alarm for a zone) E130
Burglary Restore (for a zone) R130
Fire Event (Fire Alarm for a zone) E110
Fire Restore (Fire Alarm for a zone) R110
24 Hour zone Audible Alarm Event E133
24 Hour zone Audible Alarm Restore R133
Wire Sensor Tamper Event (Zone Tamper Alarm) E144
Wire Sensor Tamper Restore (Zone Tamper Alarm) R144
RF Low Battery Event (for RF zone) E384
RF Low Battery Restore (for RF zone) R384
Loss of supervision – RF Alarm Event (for a zone) E381
Loss of supervision – RF Restore (for a zone) R381
Wireless Panic Alarm Event From Remote Control E120
Wireless Panic Alarm Restore From Remote Control R120
Sensor Trouble Event E380
Sensor Trouble Restore R380
Duress Report Event E121
Open Report Event (Disarm) E401
Close Report Event (Arm Away) R401
Partial Close Report Event (Arm Home) R441
Cancel Event (Alarm Cancel Report) E406
Silent Panic From Panel E120
Audible Panic From Panel E120
Illegal Code Alarm E461
Quick Arm R408
Forced Arm R423
Auto Arm R403
Auto Disarm E403
Remote arm/disarm (Disarm) R407
Remote arm/disarm (Arm) E407
RF receiver Jam Detect Event E344
RF receiver Jam Detect Restore R344
Low system battery Event (Panel Low Battery) E302