User's Manual
Table Of Contents
- 1. Introduction
- 2. HLX-24 Quick Reference
- 3. Specifications
- 4. Installation
- 5. Programming the HLX-24
- 6. Installer Menu
- 6.1 Change Code
- 6.2 Zones
- 6.3 Enrolling
- 6.4 Security
- 6.4.1 Exit Delay
- 6.4.2 Exit Restart
- 6.4.3 Entry Delay
- 6.4.4 Auto Arming
- 6.4.5 Siren Time
- 6.4.6 Siren Mode
- 6.4.7 Local Siren
- 6.4.8 External Siren
- 6.4.9 Supervision Time
- 6.4.10 Jamming
- 6.4.11 No Activity Time
- 6.4.12 Trouble Beeps
- 6.4.13 Bypass Option
- 6.4.14 Quick Arm
- 6.4.15 Arm Instant
- 6.4.16 Panic Button
- 6.4.17 Duress Code
- 6.4.18 Alarm Cancel
- 6.4.19 Alarm Abort Time
- 6.4.20 Backlight Time
- 6.4.21 Hide Display
- 6.4.22 Key Beeps
- 6.4.23 Select Language
- 6.4.24 EN-CENELEC
- 6.4.25 CP-01
- 6.5 Communications
- 6.6 Automation
- 6.7 Messages
- 6.8 Maintenance
- 7. User Menu Structure
- 8. Reading the Event Log
- A. Quick Reference to Installer Menu
- B. Quick Reference to User Menu
- C. Sensor Placement and Helpful Reference Tables
- D. Reporting Codes
- E. GSM Stick Errors
- F. Settings Requirements for CENELEC
- G. Default Parameter Values
- H. Labeling Instructions
- I. Declaration of Conformity
- J. Limited Warranty
Quick Reference to Installer Menu
54 HLX-24 Hardware Installation and Programming Manual
A. Quick Reference to Installer Menu
To enter the Installer menu, press Menu twice and press Enter. The default
Installer code is 8888.
The available menus are as follows:
Menu Name Menu Number
Change Code 1
Zones 2
Enrolling 3
Security 4
Communications 5
Automation 6
Messages 7
Maintenance 8
Table 12 presents some the features available in the Installer menu and how to
access them.
Table 12: Installer Menu
Feature Menu Programming Location
Exit Time
Security
Press 4 and Enter. Then press Enter.
Exit Restart
Security
Press 4 and Enter. Then press 2 and Enter.
Unvacat Premises
Security
Press 4 and Enter. Press 26 and Enter. Press
Menu until reaching “Unvacat premises” and
press Enter.
Recent Close Time
Security/CP01
Press 4 and Enter. Press Menu until reaching
“Recent Close Time”. Enter the desired value
(0–15 minutes).
Entry Delay
Security
Press 4 and Enter. Then press 3 and Enter.
Remote Arming
Enrolling
Press 3 and Enter. Press on Menu until
reaching to “Remote controls” and Enter.
Remote Disarming
Enrolling
Press 3 and Enter. Press on Menu until
reaching to “Remote controls” and Enter.
Abort Window
Zones
Press 2 and Enter. Select Zone by scrolling
with Menu and Enter. Press Menu until
reaching “Abort Window” and press Enter.
Alarm Abort Time
Security
Press 4 and Enter. Then press 20 and Enter.
Cancel Window
Security
Press 4 and Enter. Then press 19 and Enter.
Use of Duress
Feature
Security
Press 4 and Enter. Press 18 and Enter. Enter 4
digits that will be used for the user’s under
duress situation.
Duress Code
Security
Press 4 and Enter. Then press 18 and Enter.