Walk Test
When entering the detector’s Test mode, the red and green LEDs
on the panel flash every second simultaneously, and the display
shows “receiving…”.
If the alert monitoring station reporting options is enabled, an
E607 event is transmitted.
The Walk Test sequence timeout is for 15 minutes. In the last 5
minutes, a squawk is heard every two seconds in addition the
green and red LEDs flash simultaneously to indicate that the
testing period will be terminated in another five minutes.
If the system walk detector test is terminated, an R607 restore
event is transmitted (if enabled).
During the Walk Test, each successful detector violation causes a
squawk and the signal strength is displayed.
In the conclusion of the Walk Test, the installer may browse
through the recorded results by using Menu. Each browsing of a
record is followed by the E613 event transmission with the
relevant zone indication.
For 24-H and fire zones, reporting trouble event E380 is sent to
the monitoring station.
Although the system supports up to twenty users, only one master user has
access to all the settings.
To enter the user menu:
1. Press Menu until the screen displays User.
2. Press Enter.
3. Enter the Master code; the default code is 1234.
The system lockouts for 90 seconds after entering 5 wrong codes.