HLX-24 Hardware Installation and Programming Manual 45
6.5.4 Line Test
Enables you to specify the time when the phone line and CS reporting are
tested and reported to the central station, as well as the time interval between
each test (periodic reporting).
To set up line test:
1. Using Menu, select one of the two options to define, and press Enter to
confirm:
RepeatsSpecify the number of days between tests. The default is
7.
i. Using the numeric keypad, choose 1 to 30 days.
ii. Press Enter to save.
Test_Time Specify the hour of the day to perform the line test. The
test time is set at 12:00 by default
i. Using the numeric keypad, type the four digits of the desired
hour (24H convention).
ii. Press Enter to save.
6.5.5 AC Fail Report
This option allows you to specify a delay time, before reporting the power
failure to the CS, in which time power may be restored. The time is set to 0
(disabled) by default.
Power (AC) failure is indicated by the Power LED, which flashes green.
To set up AC fail report:
1. Using the numeric keypad, set the time between 1 and 240 minutes, or
set it to 0 to disable the option.
2. Press Enter to confirm and save your selection.
6.5.6 Fax Defeat
When calling the system, fax and answering machines may need to be
overridden. This menu specifies whether to enable or disable this override. By
default, this option is disabled.
To set up Fax Defeat:
1. Using Menu, Enable or Disable the option.
2. Press Enter to confirm.
6.5.7 Number of Rings
Specify the number of rings before the system answers the line. By default, this
option is set to 4 rings.