User's Manual
Table Of Contents
- 1. Introduction
- 2. HLX-24 Quick Reference
- 3. Specifications
- 4. Installation
- 5. Programming the HLX-24
- 6. Installer Menu
- 6.1 Change Code
- 6.2 Zones
- 6.3 Enrolling
- 6.4 Security
- 6.4.1 Exit Delay
- 6.4.2 Exit Restart
- 6.4.3 Entry Delay
- 6.4.4 Auto Arming
- 6.4.5 Siren Time
- 6.4.6 Siren Mode
- 6.4.7 Local Siren
- 6.4.8 External Siren
- 6.4.9 Supervision Time
- 6.4.10 Jamming
- 6.4.11 No Activity Time
- 6.4.12 Trouble Beeps
- 6.4.13 Bypass Option
- 6.4.14 Quick Arm
- 6.4.15 Arm Instant
- 6.4.16 Panic Button
- 6.4.17 Duress Code
- 6.4.18 Alarm Cancel
- 6.4.19 Alarm Abort Time
- 6.4.20 Backlight Time
- 6.4.21 Hide Display
- 6.4.22 Key Beeps
- 6.4.23 Select Language
- 6.4.24 EN-CENELEC
- 6.4.25 CP-01
- 6.5 Communications
- 6.6 Automation
- 6.7 Messages
- 6.8 Maintenance
- 7. User Menu Structure
- 8. Reading the Event Log
- A. Quick Reference to Installer Menu
- B. Quick Reference to User Menu
- C. Sensor Placement and Helpful Reference Tables
- D. Reporting Codes
- E. GSM Stick Errors
- F. Settings Requirements for CENELEC
- G. Default Parameter Values
- H. Labeling Instructions
- I. Declaration of Conformity
- J. Limited Warranty
Installer Menu
HLX-24 Hardware Installation and Programming Manual 39
Example: Setting the AC Fail parameter to enable restricts the system
from being armed until the power supply returns.
To set the access level:
1. Using Menu, select Memory Alarm, System Status, or Arm Instant.
2. Press Enter to choose the submenu.
3. Using Menu, select either Enable or Disable.
4. Press Enter to confirm.
The access level options, restricts the information actions to be accessible
to the user by pressing PIN number.
Usually system’s status information is valid to the user by pressing the
Enter key. Setting each parameter to enable, the enter key should be
followed by a PIN code.
To set the event filter:
1. Using the numeric keypad, specify the value for the event filter between 0
and 10 cycles.
2. Press Enter to save your selection.
An event filter enables the user to specify the maximum repetition of a
specific event in a session. A session is a period between each of the
arming and disarming operations.
Setting the event filter to 0 enables specific events to be recorded with no
filtering to the event log.
Setting 0, 1, 2 value in the event filter is not compatible with CENELEC
standard.
6.4.25 CP-01
The panel is not yet CP-01 standard certified
The HLX-24 supports CP-01 standard settings. During the installation process,
the installer may change each setting according to the local requirements.
The menu includes the following:
Table 9: CP01 Menu
Menu Item Description Default Setting
Abort Announce
When at least 1 zone is aborted, “ABT”
(abort) is displayed on the LCD once the
system enters Disarm mode.
Enabled
Cancel Announce
When Alarm Cancel is transmitted to the
central station, “CNL” (cancel) is
displayed on the LCD once the system
enters Disarm mode.
Enabled