6.4.22 Key Beeps
Choose to turn key beeps on to hear a beep on each key press; key beeps is on
by default.
To set the key beeps:
1. Using Menu, select one of the following options:
On to turn the key beeps on
Off to turn the key beeps off
2. Press Enter to confirm.
6.4.23 Select Language
The HLX-24 currently supports English only.
6.4.24 EN-CENELEC
The panel is not yet EN-CENELEC standard certified
The HLX-24 supports CENELEC standard settings. By default, all CENELEC
standard settings are enabled. During the installation process, the installer may
enable or disable each setting according to the local requirements.
The menu includes the following:
Status
Ready Options
Access Level
Event Filter
To set the standard status:
1. Using Menu, select either Enable or Disable.
2. Press Enter to confirm.
Enabling the standard sets all the standard features to default.
Enable state and the event filter is set to 10.
Disabling the standard sets all the standard features to disable state and the
event filter is set to 0.
To set the ready option:
1. Using Menu, select Tamper, Low Battery, AC Fail, Comm Fail, Line
Fail, Panic, or Supervision.
2. Press Enter to choose the submenu.
3. Using Menu, select either Enable or Disable.
4. Press Enter to confirm.
The ready option restricts the relevant parameters so that the system