User's Manual
Table Of Contents
- 1. Introduction
- 2. HLX-24 Quick Reference
- 3. Specifications
- 4. Installation
- 5. Programming the HLX-24
- 6. Installer Menu
- 6.1 Change Code
- 6.2 Zones
- 6.3 Enrolling
- 6.4 Security
- 6.4.1 Exit Delay
- 6.4.2 Exit Restart
- 6.4.3 Entry Delay
- 6.4.4 Auto Arming
- 6.4.5 Siren Time
- 6.4.6 Siren Mode
- 6.4.7 Local Siren
- 6.4.8 External Siren
- 6.4.9 Supervision Time
- 6.4.10 Jamming
- 6.4.11 No Activity Time
- 6.4.12 Trouble Beeps
- 6.4.13 Bypass Option
- 6.4.14 Quick Arm
- 6.4.15 Arm Instant
- 6.4.16 Panic Button
- 6.4.17 Duress Code
- 6.4.18 Alarm Cancel
- 6.4.19 Alarm Abort Time
- 6.4.20 Backlight Time
- 6.4.21 Hide Display
- 6.4.22 Key Beeps
- 6.4.23 Select Language
- 6.4.24 EN-CENELEC
- 6.4.25 CP-01
- 6.5 Communications
- 6.6 Automation
- 6.7 Messages
- 6.8 Maintenance
- 7. User Menu Structure
- 8. Reading the Event Log
- A. Quick Reference to Installer Menu
- B. Quick Reference to User Menu
- C. Sensor Placement and Helpful Reference Tables
- D. Reporting Codes
- E. GSM Stick Errors
- F. Settings Requirements for CENELEC
- G. Default Parameter Values
- H. Labeling Instructions
- I. Declaration of Conformity
- J. Limited Warranty
Installer Menu
HLX-24 Hardware Installation and Programming Manual 31
Change Code
Zones
Enrolling
SECURITY
Communications
Automation
Messages
Maintenance
Arm Instant
Panic Button
Duress Code
Alarm Cancel
Alarm Abort Time
Backlight Time
Hide Display
Key Beeps
Select Language
EN-CENELEC*
CP01
* The panel is not yet EN-CENELEC standard certified.
The fourth submenu is
SECURITY.
Browse the desired security related settings
as described in the following subsections using Menu. Press Enter to access
the desired submenu.
6.4.1 Exit Delay
An exit delay enables the user to arm the system and exit the site through a
specified door (determined as a delay zone) using a predetermined path after
arming the system, without setting off an alarm.
A progress annunciation of slow-rate warning beeps sound when the system is
armed. The system counts down the last 10 seconds of the delay if the voice
capability is configured; otherwise, the warning beeps are faster. The exit delay
is set at 60 seconds by default.
An Exit Error sequence is initiated if an entry/exit zone is in an opened state at
the instant of exit time expiration or if no delay zone is opened during the exit
time.
An Exit Error process for a delay zone is as follows:
The local alarm immediately sounds.
The annunciator sounds an Entry Delay or an alarm condition.
An Entry Delay is initiated.
If the alarm system is not Disarmed at the end of the Entry Delay, the
Alarm Transmission Sequence is initiated.
The Alarm Transmission includes the alarm and an Exit Error message to
the central station.