6.3.1 Detectors
You can enroll up to 24 detectors, one detector per zone, numbered 01
through 24.
To enroll/delete a detector:
1. Select the desired zone by either browsing all 24 zones using Menu or by
entering the zone number using the numeric keypad.
2. Select enrollment method, either Normal or Tamper.
If no detector is associated to the selected zone, the screen shows a
message saying “waiting for detector signal” for 30 seconds.
When browsing the zones, each zone already enrolled indicates "RF
ID code".
3. Press Enter to delete the detector (or ESC to go back).
4. Initiate a transmission from the detector.
In Normal enrollment any transmission is accepted (Alarm, Tamper,
or any other transmission available, see the detector’s manual for
reference).
In Tamper enrollment, only Tamper activation is accepted all other
signals are ignored.
Tamper enrollment is suitable for areas with multiple sensors thus preventing
false enrollment.
5. When the transmission is detected, you are asked to press Enter to store
the detector into the zone.
When enrolling smoke and heat detectors, make sure to select the zone type
“fire”.
If no signal is received with the allocated 30 seconds, the unit returns to
Normal mode.
6.3.2 Remote Controls (KE-30 RFID Function)
You can enroll up to eight remote controls and specify functions for each
button on the remote control. You can also delete enrolled remote controls.
Each proximity card used with the KE-30 keypad is considered a remote control
during enrollment.
To enroll a remote control or a proximity card to be used with the KE-
30 keypad and to specify a function:
1. Select the desired remote control number 01 to 08 by either browsing the
remotes using Menu or by entering the remote number using the
numeric keypad.
2. Enroll the remote control when the
WAITING FOR SIGNAL
message is
displayed, by pressing a button on the remote you wish to enroll or by
passing the proximity card through the KE-30 keypad.