User's Manual
Table Of Contents
- 1. Introduction
- 2. HLX-24 Quick Reference
- 3. Specifications
- 4. Installation
- 5. Programming the HLX-24
- 6. Installer Menu
- 6.1 Change Code
- 6.2 Zones
- 6.3 Enrolling
- 6.4 Security
- 6.4.1 Exit Delay
- 6.4.2 Exit Restart
- 6.4.3 Entry Delay
- 6.4.4 Auto Arming
- 6.4.5 Siren Time
- 6.4.6 Siren Mode
- 6.4.7 Local Siren
- 6.4.8 External Siren
- 6.4.9 Supervision Time
- 6.4.10 Jamming
- 6.4.11 No Activity Time
- 6.4.12 Trouble Beeps
- 6.4.13 Bypass Option
- 6.4.14 Quick Arm
- 6.4.15 Arm Instant
- 6.4.16 Panic Button
- 6.4.17 Duress Code
- 6.4.18 Alarm Cancel
- 6.4.19 Alarm Abort Time
- 6.4.20 Backlight Time
- 6.4.21 Hide Display
- 6.4.22 Key Beeps
- 6.4.23 Select Language
- 6.4.24 EN-CENELEC
- 6.4.25 CP-01
- 6.5 Communications
- 6.6 Automation
- 6.7 Messages
- 6.8 Maintenance
- 7. User Menu Structure
- 8. Reading the Event Log
- A. Quick Reference to Installer Menu
- B. Quick Reference to User Menu
- C. Sensor Placement and Helpful Reference Tables
- D. Reporting Codes
- E. GSM Stick Errors
- F. Settings Requirements for CENELEC
- G. Default Parameter Values
- H. Labeling Instructions
- I. Declaration of Conformity
- J. Limited Warranty
Installer Menu
26 HLX-24 Hardware Installation and Programming Manual
4. Press Enter to access the desired submenu to define several characteristics
as follows:
Zone Type: Select one of the following:
Delay – An opening in this zone is alarmed only after the exit or
entry time has passed
Fire – An opening in this zone causes a fire alarm and is armed
24 hours a day
24H Silent – An opening in this zone causes a silent alarm (no
audible local siren) and is armed 24 hours a day
24H Audible – An opening in this zone causes an audible alarm
and is armed 24 hours a day
No Secure – non-alarm zone – zone can be used for any non-
secured propose
Interior – Zone is bypassed when system is in Arm Home (Stay)
mode
Interior Follow – A non-entry/exit zone, typically an interior zone
located on an entry/exit path, which is treated as an entry/exit
zone during an Entry Delay or Exit Time. An opening in this zone
is alarmed only after the exit or entry time has passed.
Perimeter – Zone is armed both in Arm Home and Arm Away
modes
Description: Select one of 38 fixed descriptions or one of five
editable custom descriptions. HLX-24 enables you to specify five
custom zones (see Section 6.7.3).
For your convenience and better control of the installation, use the
tables provided in Appendix C.
No Activity: Select to enable or disable the no activity time for each
zone. When there is no activity in the specified zone and the system
is disarmed, a silent alarm is sent to the monitoring station. When the
system is armed and there is no activity in the specified zone, an
audible alarm and a report are sent to the monitoring station. By
default the option is disabled.
Swinger: Select the number of repeated opening events from the
zone after which the system ignores the zone. The default setting is 2
zone openings. The zone is restored after a manual system reset or
automatically after a defined number of hours. The default value is 8
hours.
Zone cross: The zone cross option requires an opening of two zones
within a given time period to initiate an Alarm event sequence. This
setting links between the two zones.