User's Manual
Table Of Contents
- 1. Introduction
- 2. HLX-24 Quick Reference
- 3. Specifications
- 4. Installation
- 5. Programming the HLX-24
- 6. Installer Menu
- 6.1 Change Code
- 6.2 Zones
- 6.3 Enrolling
- 6.4 Security
- 6.4.1 Exit Delay
- 6.4.2 Exit Restart
- 6.4.3 Entry Delay
- 6.4.4 Auto Arming
- 6.4.5 Siren Time
- 6.4.6 Siren Mode
- 6.4.7 Local Siren
- 6.4.8 External Siren
- 6.4.9 Supervision Time
- 6.4.10 Jamming
- 6.4.11 No Activity Time
- 6.4.12 Trouble Beeps
- 6.4.13 Bypass Option
- 6.4.14 Quick Arm
- 6.4.15 Arm Instant
- 6.4.16 Panic Button
- 6.4.17 Duress Code
- 6.4.18 Alarm Cancel
- 6.4.19 Alarm Abort Time
- 6.4.20 Backlight Time
- 6.4.21 Hide Display
- 6.4.22 Key Beeps
- 6.4.23 Select Language
- 6.4.24 EN-CENELEC
- 6.4.25 CP-01
- 6.5 Communications
- 6.6 Automation
- 6.7 Messages
- 6.8 Maintenance
- 7. User Menu Structure
- 8. Reading the Event Log
- A. Quick Reference to Installer Menu
- B. Quick Reference to User Menu
- C. Sensor Placement and Helpful Reference Tables
- D. Reporting Codes
- E. GSM Stick Errors
- F. Settings Requirements for CENELEC
- G. Default Parameter Values
- H. Labeling Instructions
- I. Declaration of Conformity
- J. Limited Warranty
Specifications
16 HLX-24 Hardware Installation and Programming Manual
3. Specifications
This chapter provides the various specifications for the HLX-24 control panel.
3.1 RF Data
RF Unit Type
Integrated RF transceiver shielded super heterodyne, fixed
frequency
Antenna Type
Printed PCB type antenna
Operating
Frequencies
G series – 433.92 MHz
H series – 868.35 MHz
Receiver
Sensitivity
Up to -100 dBm
Transmitter
Power
Up to +10 dBm, less based on country requirements
Range
(open field)
Up to 170 m (558 ft) in open space for detectors, and 110 m (361
ft) for hand-held remote controls
RF Device ID
Coding
Three-bytes non-replicated per sensor type, or multiples of 16
million possible codes, make it almost impossible to have two like
coded transmitters
The HLX-24 system has optimum range if installed according to the
manufacturer’s recommendations, though this range may be affected by radio
noise from high-power nearby sources, or interference with the signal
(blocking) by large metal surfaces, or multiple concrete walls.
3.2 Environmental Data
Operation Temperature Range 0ºC to 40ºC (32ºF to 104ºF)
Storage Temperature Range -25ºC to 70ºC (-13ºF to 158ºF)
Relative Humidity 85% at 30ºC (non-condensing)
Dimensions
(L x W x D)
174 x 152 x 48 mm
(8.5 x 5.7 x 1.9 in.)
Weight 330 g (11.6 oz)
3.3 Electrical Data
Two lines of 16 characters, backlit LCD display
One PGM open collector outputs, 100 mA, PTC protected
Local, 85 dBA siren
220 VAC/50 Hz, 110 VAC/60 Hz (15 VDC, 800 mA) external power supply
Complies with the following standards:
CE, FCC