User's Manual

Table Of Contents
Specifications
16 HLX-24 Hardware Installation and Programming Manual
3. Specifications
This chapter provides the various specifications for the HLX-24 control panel.
3.1 RF Data
RF Unit Type
Integrated RF transceiver shielded super heterodyne, fixed
frequency
Antenna Type
Printed PCB type antenna
Operating
Frequencies
G series 433.92 MHz
H series 868.35 MHz
Receiver
Sensitivity
Up to -100 dBm
Transmitter
Power
Up to +10 dBm, less based on country requirements
Range
(open field)
Up to 170 m (558 ft) in open space for detectors, and 110 m (361
ft) for hand-held remote controls
RF Device ID
Coding
Three-bytes non-replicated per sensor type, or multiples of 16
million possible codes, make it almost impossible to have two like
coded transmitters
The HLX-24 system has optimum range if installed according to the
manufacturer’s recommendations, though this range may be affected by radio
noise from high-power nearby sources, or interference with the signal
(blocking) by large metal surfaces, or multiple concrete walls.
3.2 Environmental Data
Operation Temperature Range C to 4C (32ºF to 104ºF)
Storage Temperature Range -25ºC to 70ºC (-1F to 158ºF)
Relative Humidity 85% at 30ºC (non-condensing)
Dimensions
(L x W x D)
174 x 152 x 48 mm
(8.5 x 5.7 x 1.9 in.)
Weight 330 g (11.6 oz)
3.3 Electrical Data
Two lines of 16 characters, backlit LCD display
One PGM open collector outputs, 100 mA, PTC protected
Local, 85 dBA siren
220 VAC/50 Hz, 110 VAC/60 Hz (15 VDC, 800 mA) external power supply
Complies with the following standards:
CE, FCC