AY-B9350 User Manual 48
3.7.3. Input setting
Select [Terminal]
[Input] in the main menu to display the screen below.
▶
Default setting: same with the setting in the left
screen
▶ M0: Set this to connect an external contact to DM0.
(If motor lock is used, set it to [door open status NO] or [door open status NC].)
- Not use: Select this when nothing is connected.
- Door open status NO or door open status NC: when door open status monitoring pin
is connected.
Set NO/NC according to status of pin which is input during detection.
▶ M1/M2: Set this to connect an external contact to DM1/DM2.
(If motor lock is used, set it to [locked status NO] or [lock status NC].)
- Not use: Select this when nothing is connected.
- Locked status NO or locked status NC: when locked status monitoring pin is
connected
Set NO/NC according to status of pin which is input during detection
▶ IO: Set this to connect an external contact to Exit pin.
- Not use: select this when nothing is connected
- Inside Open NO or Inside Open NC: Exit button is connected
Set NO/NC according to status of pin which is input during detection
▶ Warn Door open (sec)
This function makes the terminal to check door Open time to make a warning sound if
the door is open more than the setting time (min 5 seconds ~ max 60 seconds).
If it is set to [0], no warning sound will be made. Warning sound will be started after
min 5 seconds even when it is set to [01~04].
The door must be closed within the setting time. If not due to unexpected situation,
the terminal will make warning sound to inform the situation administrator to take
measures for normal door closing.
To use this function, monitoring of the Lock for door open lock status must be possible,