AY-R6255 Illuminated RFID Reader Installation and Operational Manual
Copyright © 2015 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information. No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
Table of Contents Table of Contents 1. Introduction ................................................................ 7 2. Technical Specifications .............................................. 8 3. Mounting Instructions ................................................ 9 4. Wiring Instructions ................................................... 10 5. Operating Instructions .............................................. 12 5.1 Lighting .............................................................
List of Figures List of Figures Figure 1: Mounting Template ............................................................................
List of Tables List of Tables Table 1: Wiring Colors .....................................................................................10 Table 2: Operations Table ................................................................................12 Table 3: Output Format ...................................................................................13 Table 4: Read Format.......................................................................................
Notice and Disclaimer Notice and Disclaimer This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product described herein. BEFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES. The system must not be used for purposes other than those for which it was designed.
Introduction 1. Introduction The AY-R6255 is 13.56 MHz RFID reader and is installed when using access control systems. This is a unique product that has a variety of options to control the reader's illumination according to various settings. An example of this are the settings that enable users to set the reader to project green light when everything is normal and red in case of emergency; this is done by adjusting the inputs accordingly.
Technical Specifications 2. Technical Specifications Electrical Characteristics Power Supply Type Linear (recommended) Operating Voltage Range 12–16 VDC Maximum Input Current Standby: 100 mA Read: 250 mA Tamper Output Open collector, active low, max. sink current 16 mA Read Range* (max) MIFARE Classic EV1®: 7 cm (2.8 in.) Felica/MIFARE Plus®/DESFire®: 3 cm (1.2 in.) ISO1443B: 5 cm (2.0 in.) China ID: 2 cm (0.8 in.) Maximum Cable Distance to Controller 150 m (500 ft) RE Modulation ASK @ 13.
Mounting Instructions 3. Mounting Instructions Installation of an RFID reader adjacent to metallic surfaces might alter the reader’s specifications. To diminish this interference, use a plastic spacer when mounting the reader. When mounting the reader, you must remove the snap-off cover to access the screw holes. To mount the reader: 1. Determine an appropriate mounting position for the reader. 2. Screw off the back of the unit and place it at the desired mounting position. 3.
Wiring Instructions 4. Wiring Instructions The AY-R6255 is supplied with a 10-wire 45-cm (18”) pigtail, comprising a 6-conductor cable. To connect the reader to the controller: 1. Prepare the reader cable by cutting its jacket back 4.5 cm (1¼”) and strip the wires 1.3 cm (½”). 2. Prepare the controller cable by cutting its jacket back 3.2 cm (1¼”) and stripping the wires 1.3 cm (½”). 3. Splice the reader’s pigtail wires to the corresponding controller wires and cover each connection.
Wiring Instructions 4. Trim and cover all unused conductors. • The individual wires from the reader are color-coded according the Wiegand standard. • When using a separate power supply for the reader, this supply and that of the controller, must have a common ground. • The reader’s cable shield wire should preferably be attached to an earth ground, or a signal ground connection at the panel, or power supply end of he cable.
Operating Instructions 5. Operating Instructions 5.1 Lighting Table 2 shows the settings for Set 0 through Set 3, which determine the color of the unit’s lighting.
Operating Instructions 5.2 DIP Switch Settings for Output and Input Formats Setting the DIP Switches of Pins 1 and 2 determine the output format of the reader (Table 3), while Pins 3 and 4 determine the card format that is read (Table 4). Pins 5 through 8 are for future use. Table 3: Output Format Pin 1 Pin 2 Output 0 0 Wiegand 26-Bit 0 1 Wiegand 32-Bit 1 0 Wiegand 34-Bit 1 1 Wiegand 40-Bit Table 4: Read Format Pin 3 Pin 4 Read 0 0 ISO14443A 0 1 ISO14444B 1 0 ISO15693.Felica.
Testing the Reader 6. Testing the Reader Once the reader has been wired to a power supply and the controller, it should be tested. To test the reader: 1. Power up the reader. The beeper activates 3 times after which the LED lights up green (according to Set 0, Set 1, Set 2, and Set 3 setup). This indicates that the reader is working properly. The default is that the reader switches colors circularly. The color can be set according to the input wires. 2.
Limited Warranty A. Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
Caution: This device complies with Part 15 of the FCC rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or change to this equipment.
AY-R6255 Asia Pacific, Middle East, Africa Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com United States and Canada Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com Europe Latin America Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.