Technical Specs

6.2. R estore to Factory Defaults
To restore the reader to default settings, before power-on, connect the orange wire (green LED control) and yellow
wire (Buzzer Control) to GND for two or more seconds. The red LED will turn ON for 2 seconds, followed by a long
two second beep. This indicates successful Multi-Smart™ Readers power up with default settings.
6.3. Standby Mode
In standby mode, two LED bars will be in steady RED condition.
EM 125 KHz And CSN 13.56 MHz Credential Read
When a 125 kHz credential or a 13.56 MHz credential is detected by the reader, both LED bars will flash GREEN for
250ms, and the reader will sound short beep for 300ms. This indicates a successful card read and transfer on the
Wiegand port. Then, the reader will return to standby mode and the right light bar stays solid RED.
Multi-Smart™ Readers Installation & User Guide
www.rosslaresecurity.com
8