12 AY-H6355BT Installation and User Manual
4. Wiring Instructions
The units are supplied with a 10-conductor 5-m (16-ft) pigtail with
exposed wires coated with solder.
To connect the unit as a reader to an access control unit:
1. Select the appropriate connections according to Table 1.
2. Prepare the controller cable by cutting its jacket back about 3 cm
(1¼") and strip the insulation from the wires about 1.3 cm (½").
3. Splice the reader’s pigtail wires to the corresponding controller
wires and cover each joint with insulating tape.
Table 1: Wiring the Unit as a Reader to a Control Panel
Wire Color Output
Red Power
Black Ground
Green Data 0 / Data / C2
White Data 1 / Clock / C1
Orange Green LED Control*
Brown Yellow LED Control*
Purple Tamper Output
Yellow Buzzer Control*
Blue RS-485 - A / OSDP**
Gray RS-485 - B / OSDP**
* These wires have programmable functions that may be adjusted by
presenting a configuration card within 10 seconds upon powering on the
unit. See the
CS-CCT Configuration Card Tool for the DR-6255 Software
Manual
for how you can create a configuration card.
** RS-485 is used for firmware update.