User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. Reader Operation
- 6. OSDP Operation
- 7. Reader Functionality
- 7.1 Transmit Mode
- 7.2 Programming the AYC-x6355 Series
- 7.2.1 Entering Programming Mode
- 7.2.2 Exiting Programming Mode
- 7.2.3 Selecting Keypad Transmission Format
- 7.2.3.1 Keypad Transmission Format Option Number
- Option 1: Single Key, Wiegand 6-Bit (Rosslare Format)
- Option 2: Single Key, Wiegand 6-Bit Nibble and Parities
- Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented
- Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit
- Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
- Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit
- Option 7: 1 to 8 Keys BCD, Clock & Data
- Option 8: Single Key, Wiegand 4-Bit
- 7.2.3.1 Keypad Transmission Format Option Number
- 7.2.4 Selecting Proximity Card Transmission Format
- 7.2.5 Changing the Programming Code
- 7.2.6 Changing the Facility Code
- 7.3 Setting the Backlight
- 7.4 Return to Factory Default Settings
- 7.5 Replacing a Lost Programming Code
- 8. Controller Functionality
- 8.1 Normal, Secure, and Master Users
- 8.2 Modes of Operation
- 8.3 Auxiliary Input and Output
- 8.4 Door Alarms
- 8.5 Internal Case and Back Tamper
- 8.6 Lockout Feature (Keypad/Card Tamper)
- 8.7 REX Function
- 8.8 Secure Application Appurtenances
- 8.9 Programming the AYC-x6355
- 8.9.1 Entering Programming Mode
- 8.9.2 Exiting Programming Mode
- 8.9.3 Changing Lock Strike Code
- 8.9.4 Changing Auxiliary Code
- 8.9.5 Changing the Programming Code
- 8.9.6 Changing the Normal/Secure Code
- 8.9.7 Changing the Normal/Bypass Code and Door Chime Settings
- 8.9.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 8.9.9 Defining the Auxiliary Input and Output
- 8.9.10 Detailed Reference Guide
- 8.9.11 Setting the Lockout Feature
- 8.9.12 Setting the Backlight Behavior
- 8.9.13 Enrolling Primary and Secondary Codes
- 8.9.14 Deleting Primary and Secondary Codes
- 8.9.15 Relay Codes Assignment
- 8.9.16 Relay Code Assignment using Standard Method
- 8.9.17 Relay Code Assignment using Search Method
- 8.9.18 PIN Code Length/Factory Default Settings
- 8.9.19 Replacing a Lost Programming Code
- 8.9.20 Exiting Secure Mode if Normal/Secure Code was Lost
- A. Declaration of Conformity
- B. Limited Warranty
Controller Functionality
AYC-x6355 Installation and User Manual 53
Secondary codes cannot be the same as any system codes, such
as the Normal/Secure or Lock Strike codes.
Users who hold Secondary codes can gain entry in any mode of
operation.
8.9.13.3 Enrolling Primary and Secondary Codes
There are two methods to enroll Primary and Secondary codes:
Standard Method
The Standard Method is mainly used when the user slot number
for the user you wish to program is known. You can program
both Primary and Secondary codes using the Standard method
(see Section 8.9.13.4).
Code Search Method
The Code Search Method is mainly used when enrolling a user’s
Secondary code and the user slot code is unknown.
The Code Search method only works if a user’s Primary code is
already enrolled but the Secondary code is not (see
Section 8.9.13.5).
8.9.13.4 Enrolling Primary & Secondary Codes using Standard
Method
1. Enter Programming mode.
2. Press 7 to enter Menu 7.
The Door LED turns orange.
3. Enter the 3-
digit user slot number
between 001and 500 that you
wish to enroll a Primary or
Secondary code to.
For example, User Slot 003
represents User #3.
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Orange