User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. Reader Operation
- 6. OSDP Operation
- 7. Reader Functionality
- 7.1 Transmit Mode
- 7.2 Programming the AYC-x6355 Series
- 7.2.1 Entering Programming Mode
- 7.2.2 Exiting Programming Mode
- 7.2.3 Selecting Keypad Transmission Format
- 7.2.3.1 Keypad Transmission Format Option Number
- Option 1: Single Key, Wiegand 6-Bit (Rosslare Format)
- Option 2: Single Key, Wiegand 6-Bit Nibble and Parities
- Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented
- Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit
- Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
- Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit
- Option 7: 1 to 8 Keys BCD, Clock & Data
- Option 8: Single Key, Wiegand 4-Bit
- 7.2.3.1 Keypad Transmission Format Option Number
- 7.2.4 Selecting Proximity Card Transmission Format
- 7.2.5 Changing the Programming Code
- 7.2.6 Changing the Facility Code
- 7.3 Setting the Backlight
- 7.4 Return to Factory Default Settings
- 7.5 Replacing a Lost Programming Code
- 8. Controller Functionality
- 8.1 Normal, Secure, and Master Users
- 8.2 Modes of Operation
- 8.3 Auxiliary Input and Output
- 8.4 Door Alarms
- 8.5 Internal Case and Back Tamper
- 8.6 Lockout Feature (Keypad/Card Tamper)
- 8.7 REX Function
- 8.8 Secure Application Appurtenances
- 8.9 Programming the AYC-x6355
- 8.9.1 Entering Programming Mode
- 8.9.2 Exiting Programming Mode
- 8.9.3 Changing Lock Strike Code
- 8.9.4 Changing Auxiliary Code
- 8.9.5 Changing the Programming Code
- 8.9.6 Changing the Normal/Secure Code
- 8.9.7 Changing the Normal/Bypass Code and Door Chime Settings
- 8.9.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 8.9.9 Defining the Auxiliary Input and Output
- 8.9.10 Detailed Reference Guide
- 8.9.11 Setting the Lockout Feature
- 8.9.12 Setting the Backlight Behavior
- 8.9.13 Enrolling Primary and Secondary Codes
- 8.9.14 Deleting Primary and Secondary Codes
- 8.9.15 Relay Codes Assignment
- 8.9.16 Relay Code Assignment using Standard Method
- 8.9.17 Relay Code Assignment using Search Method
- 8.9.18 PIN Code Length/Factory Default Settings
- 8.9.19 Replacing a Lost Programming Code
- 8.9.20 Exiting Secure Mode if Normal/Secure Code was Lost
- A. Declaration of Conformity
- B. Limited Warranty
Controller Functionality
46 AYC-x6355 Installation and User Manual
Table 5: Quick Reference Guide for Auxiliary Mode Setting
Aux. Mode Aux. Input
Function
Aux. Output
Activated by
Aux. Relay Aux. Settings
(in seconds)
0 AUX REX Valid code or AUX
REX
N.O. 01 to 99 Aux. relay
release time
1 Normal/Secure switch Valid code N.O. 01 to 99 Aux. relay
release time
2 Normal/Secure switch Star button () N.O. 01 to 99 Aux. relay
release time
3 Normal/Secure switch Tamper event N.C. 01 to 99 Aux. relay
release time
6 Door Monitor Forced door N.C. 01 to 99 Forced delay
7 Door Monitor Door ajar N.C.
01 to 99 Ajar delay
8 LED control – Green Valid code N.O. 01 to 99 Aux. relay
release time
9 LED control – Red Valid code N.O. 01 to 99 Aux. relay
release time