User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. OSDP Operation
- 6. Reader Functionality
- 6.1 Transmit Mode
- 6.2 Programming as a Reader
- 6.3 Setting the Backlight
- 6.4 Return to Factory Default Settings
- 6.5 Replacing a Lost Programming Code
- 7. Controller Functionality
- 7.1 Normal, Secure, and Master Users
- 7.2 Modes of Operation
- 7.3 Auxiliary Input and Output
- 7.4 Door Alarms
- 7.5 Internal Case and Back Tamper
- 7.6 Lockout Feature (Keypad/Card Tamper)
- 7.7 REX Function
- 7.8 Secured Intelligent Power Supply
- 7.9 Programming as a Controller
- 7.9.1 Entering Programming Mode
- 7.9.2 Exiting Programming Mode
- 7.9.3 Changing Lock Strike Code
- 7.9.4 Changing Auxiliary Code
- 7.9.5 Changing the Programming Code
- 7.9.6 Changing the Normal/Secure Code
- 7.9.7 Changing the Normal/Bypass Code and Door Chime Settings
- 7.9.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 7.9.9 Defining the Auxiliary Input and Output
- 7.9.10 Auxiliary Mode Reference Guide
- 7.9.11 Setting the Lockout Feature
- 7.9.12 Setting the Backlight Behavior
- 7.9.13 Setting the Bell Button (*) Behavior
- 7.9.14 Enrolling Primary and Secondary Codes
- 7.9.15 Deleting Primary and Secondary Codes
- 7.9.16 Relay Codes Assignment
- 7.9.17 Relay Code Assignment using Standard Method
- 7.9.18 Relay Code Assignment using Search Method
- 7.9.19 PIN Code Length/Factory Default Settings
- 7.9.20 Replacing a Lost Programming Code
- 7.9.21 Exiting Secure Mode if Normal/Secure Code was Lost
- A. Declaration of Conformity
- B. Limited Warranty
Controller Functionality
AYC-x6355 (Rev. A) Installation and User Manual 53
7.9.11 Setting the Lockout Feature
If the controller is presented with wrong codes several times
consecutively, the unit goes into Lockout mode.
When a lockout occurs, the controller keypad and reader are locked
so no codes can be entered until the set lockout period expires.
During Lockout, the left LED is Off, the right LED flashes red, and the
controller beeps every two seconds.
The default setting for the Lockout Feature is 4000 (Lockout
Disabled).
Using the lockout feature is highly recommended, especially
when selecting to use short PIN code length (4 or 5 digits).
To set the lockout feature:
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The left LED flashes green.
3. Construct a code using the following
instructions:
Second digit
Set the number of wrong code attempts, which causes a
Lockout between 0 and 9 attempts.
Third and fourth digits
Sets the Duration of the lockout, between 00 and 99; the
value is multiplied by ten, resulting in 0 to 990 seconds.
Green
Green
Green