User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. OSDP Operation
- 6. Reader Functionality
- 6.1 Transmit Mode
- 6.2 Programming as a Reader
- 6.3 Setting the Backlight
- 6.4 Return to Factory Default Settings
- 6.5 Replacing a Lost Programming Code
- 7. Controller Functionality
- 7.1 Normal, Secure, and Master Users
- 7.2 Modes of Operation
- 7.3 Auxiliary Input and Output
- 7.4 Door Alarms
- 7.5 Internal Case and Back Tamper
- 7.6 Lockout Feature (Keypad/Card Tamper)
- 7.7 REX Function
- 7.8 Secured Intelligent Power Supply
- 7.9 Programming as a Controller
- 7.9.1 Entering Programming Mode
- 7.9.2 Exiting Programming Mode
- 7.9.3 Changing Lock Strike Code
- 7.9.4 Changing Auxiliary Code
- 7.9.5 Changing the Programming Code
- 7.9.6 Changing the Normal/Secure Code
- 7.9.7 Changing the Normal/Bypass Code and Door Chime Settings
- 7.9.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 7.9.9 Defining the Auxiliary Input and Output
- 7.9.10 Auxiliary Mode Reference Guide
- 7.9.11 Setting the Lockout Feature
- 7.9.12 Setting the Backlight Behavior
- 7.9.13 Setting the Bell Button (*) Behavior
- 7.9.14 Enrolling Primary and Secondary Codes
- 7.9.15 Deleting Primary and Secondary Codes
- 7.9.16 Relay Codes Assignment
- 7.9.17 Relay Code Assignment using Standard Method
- 7.9.18 Relay Code Assignment using Search Method
- 7.9.19 PIN Code Length/Factory Default Settings
- 7.9.20 Replacing a Lost Programming Code
- 7.9.21 Exiting Secure Mode if Normal/Secure Code was Lost
- A. Declaration of Conformity
- B. Limited Warranty
Controller Functionality
AYC-x6355 (Rev. A) Installation and User Manual 51
the second door. The REX feature for the second door is not enabled
when using this mode.
The auxiliary setting defines the door open time for the second door.
The auxiliary input can switch the mode of operation of the controller
between Normal and Secure modes. By connecting a switch timer or
alarm system output to the auxiliary input, the controller can be
automatically switched from Normal mode (during office hours) to
Secure mode (after office hours).
7.9.10.3 Auxiliary Mode 2
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: * Button
For example, in Auxiliary Mode 2, the auxiliary relay can function as a
general purpose time switch that can be activated when * is pressed.
The auxiliary setting establishes for how long the auxiliary relay is to
be activated. The auxiliary input can switch the mode of operation of
the controller between Normal and Secure modes. By connecting a
switch timer or alarm system output to the auxiliary input, the
controller can be automatically switched from Normal mode (during
office hours) to Secure mode (after office hours).
7.9.10.4 Auxiliary Mode 3
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: Alarms
For example, in Auxiliary Mode 3, the auxiliary output is activated if
the controller is tampered; that is, if the case is forcibly opened or
removed from the wall. The auxiliary input can switch the mode of
operation of the controller between Normal and Secure modes. By
connecting a switch timer or alarm system output to the auxiliary
input, the controller can be automatically switched from Normal
mode (during office hours) to Secure mode (after office hours).