User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. OSDP Operation
- 6. Reader Functionality
- 6.1 Transmit Mode
- 6.2 Programming as a Reader
- 6.3 Setting the Backlight
- 6.4 Return to Factory Default Settings
- 6.5 Replacing a Lost Programming Code
- 7. Controller Functionality
- 7.1 Normal, Secure, and Master Users
- 7.2 Modes of Operation
- 7.3 Auxiliary Input and Output
- 7.4 Door Alarms
- 7.5 Internal Case and Back Tamper
- 7.6 Lockout Feature (Keypad/Card Tamper)
- 7.7 REX Function
- 7.8 Secured Intelligent Power Supply
- 7.9 Programming as a Controller
- 7.9.1 Entering Programming Mode
- 7.9.2 Exiting Programming Mode
- 7.9.3 Changing Lock Strike Code
- 7.9.4 Changing Auxiliary Code
- 7.9.5 Changing the Programming Code
- 7.9.6 Changing the Normal/Secure Code
- 7.9.7 Changing the Normal/Bypass Code and Door Chime Settings
- 7.9.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 7.9.9 Defining the Auxiliary Input and Output
- 7.9.10 Auxiliary Mode Reference Guide
- 7.9.11 Setting the Lockout Feature
- 7.9.12 Setting the Backlight Behavior
- 7.9.13 Setting the Bell Button (*) Behavior
- 7.9.14 Enrolling Primary and Secondary Codes
- 7.9.15 Deleting Primary and Secondary Codes
- 7.9.16 Relay Codes Assignment
- 7.9.17 Relay Code Assignment using Standard Method
- 7.9.18 Relay Code Assignment using Search Method
- 7.9.19 PIN Code Length/Factory Default Settings
- 7.9.20 Replacing a Lost Programming Code
- 7.9.21 Exiting Secure Mode if Normal/Secure Code was Lost
- A. Declaration of Conformity
- B. Limited Warranty
Controller Functionality
50 AYC-x6355 (Rev. A) Installation and User Manual
Table 7: Quick Reference Guide for Auxiliary Mode Setting
Aux.
Mode
Aux. Input
Function
Aux. Output
Activated by
Aux.
Relay
Aux. Settings
(in seconds)
0 AUX REX Valid code or AUX
REX
N.O. 01 to 99 Aux. relay
release time
1 Normal/Secure
switch
Valid code N.O. 01 to 99 Aux. relay
release time
2 Normal/Secure
switch
Star button (*) N.O. 01 to 99 Aux. relay
release time
3 Normal/Secure
switch
Tamper event N.C. 01 to 99 Aux. relay
release time
6 Door Monitor Forced door N.C. 01 to 99 Forced
delay
7 Door Monitor Door ajar N.C.
01 to 99 Ajar delay
7.9.10 Auxiliary Mode Reference Guide
The following are brief descriptions of each auxiliary mode. To
implement the features of each mode, refer to Section 7.9.9.
7.9.10.1 Auxiliary Mode 0
Auxiliary input function: Activates the auxiliary output
Auxiliary output activated by: Valid user code, Auxiliary code, and
Auxiliary input
For example, in Auxiliary Mode 0, the controller can function as a
2-door controller. The auxiliary relay is to be attached to the lock on
the second door. The auxiliary setting defines the door open time for
the second door. The auxiliary input is to be attached to the REX
pushbutton for the second door. The Door Monitor input feature for
the second door is not enabled when using this mode.
7.9.10.2 Auxiliary Mode 1
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 1, the controller can function as a
2-door controller. The auxiliary relay is to be attached to the lock on