Controller Functionality
50 AYC-x6355 (Rev. A) Installation and User Manual
Table 7: Quick Reference Guide for Auxiliary Mode Setting
Aux.
Mode
Aux. Input
Function
Aux. Output
Activated by
Aux.
Relay
Aux. Settings
(in seconds)
0 AUX REX Valid code or AUX
REX
N.O. 01 to 99 Aux. relay
release time
1 Normal/Secure
switch
Valid code N.O. 01 to 99 Aux. relay
release time
2 Normal/Secure
switch
Star button (*) N.O. 01 to 99 Aux. relay
release time
3 Normal/Secure
switch
Tamper event N.C. 01 to 99 Aux. relay
release time
6 Door Monitor Forced door N.C. 01 to 99 Forced
delay
7 Door Monitor Door ajar N.C.
01 to 99 Ajar delay
7.9.10 Auxiliary Mode Reference Guide
The following are brief descriptions of each auxiliary mode. To
implement the features of each mode, refer to Section 7.9.9.
7.9.10.1 Auxiliary Mode 0
Auxiliary input function: Activates the auxiliary output
Auxiliary output activated by: Valid user code, Auxiliary code, and
Auxiliary input
For example, in Auxiliary Mode 0, the controller can function as a
2-door controller. The auxiliary relay is to be attached to the lock on
the second door. The auxiliary setting defines the door open time for
the second door. The auxiliary input is to be attached to the REX
pushbutton for the second door. The Door Monitor input feature for
the second door is not enabled when using this mode.
7.9.10.2 Auxiliary Mode 1
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 1, the controller can function as a
2-door controller. The auxiliary relay is to be attached to the lock on