User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. OSDP Operation
- 6. Reader Functionality
- 6.1 Transmit Mode
- 6.2 Programming as a Reader
- 6.3 Setting the Backlight
- 6.4 Return to Factory Default Settings
- 6.5 Replacing a Lost Programming Code
- 7. Controller Functionality
- 7.1 Normal, Secure, and Master Users
- 7.2 Modes of Operation
- 7.3 Auxiliary Input and Output
- 7.4 Door Alarms
- 7.5 Internal Case and Back Tamper
- 7.6 Lockout Feature (Keypad/Card Tamper)
- 7.7 REX Function
- 7.8 Secured Intelligent Power Supply
- 7.9 Programming as a Controller
- 7.9.1 Entering Programming Mode
- 7.9.2 Exiting Programming Mode
- 7.9.3 Changing Lock Strike Code
- 7.9.4 Changing Auxiliary Code
- 7.9.5 Changing the Programming Code
- 7.9.6 Changing the Normal/Secure Code
- 7.9.7 Changing the Normal/Bypass Code and Door Chime Settings
- 7.9.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 7.9.9 Defining the Auxiliary Input and Output
- 7.9.10 Auxiliary Mode Reference Guide
- 7.9.11 Setting the Lockout Feature
- 7.9.12 Setting the Backlight Behavior
- 7.9.13 Setting the Bell Button (*) Behavior
- 7.9.14 Enrolling Primary and Secondary Codes
- 7.9.15 Deleting Primary and Secondary Codes
- 7.9.16 Relay Codes Assignment
- 7.9.17 Relay Code Assignment using Standard Method
- 7.9.18 Relay Code Assignment using Search Method
- 7.9.19 PIN Code Length/Factory Default Settings
- 7.9.20 Replacing a Lost Programming Code
- 7.9.21 Exiting Secure Mode if Normal/Secure Code was Lost
- A. Declaration of Conformity
- B. Limited Warranty
Controller Functionality
AYC-x6355 (Rev. A) Installation and User Manual 45
7.9.4 Changing Auxiliary Code
The Auxiliary code is mainly used as a method to quickly test the
Auxiliary Relay during installation.
When the first user is added to the controller, the default Auxiliary
code is automatically deleted. Once the code is programmed again, it
is not deleted with the entry of additional user codes.
To change the Auxiliary code:
• Auxiliary code does not work in the Secure mode.
• Wrong entries return the controller to Normal mode.
• Code 0000 erases the Auxiliary code.
• The factory default 4-digit Auxiliary code is 0852.
To change the Auxiliary code:
1. Enter Programming mode.
2. Press 2 to enter Menu 2.
The left LED turns orange.
3. Enter the new code you wish to set as the
Auxiliary code.
You hear three beeps.
The system returns to Normal mode.
Green
Orange
Green
Green