User's Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Mounting
- 4. Wiring Instructions
- 5. OSDP Operation
- 6. Reader Functionality
- 6.1 Transmit Mode
- 6.2 Programming as a Reader
- 6.3 Setting the Backlight
- 6.4 Return to Factory Default Settings
- 6.5 Replacing a Lost Programming Code
- 7. Controller Functionality
- 7.1 Normal, Secure, and Master Users
- 7.2 Modes of Operation
- 7.3 Auxiliary Input and Output
- 7.4 Door Alarms
- 7.5 Internal Case and Back Tamper
- 7.6 Lockout Feature (Keypad/Card Tamper)
- 7.7 REX Function
- 7.8 Secured Intelligent Power Supply
- 7.9 Programming as a Controller
- 7.9.1 Entering Programming Mode
- 7.9.2 Exiting Programming Mode
- 7.9.3 Changing Lock Strike Code
- 7.9.4 Changing Auxiliary Code
- 7.9.5 Changing the Programming Code
- 7.9.6 Changing the Normal/Secure Code
- 7.9.7 Changing the Normal/Bypass Code and Door Chime Settings
- 7.9.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 7.9.9 Defining the Auxiliary Input and Output
- 7.9.10 Auxiliary Mode Reference Guide
- 7.9.11 Setting the Lockout Feature
- 7.9.12 Setting the Backlight Behavior
- 7.9.13 Setting the Bell Button (*) Behavior
- 7.9.14 Enrolling Primary and Secondary Codes
- 7.9.15 Deleting Primary and Secondary Codes
- 7.9.16 Relay Codes Assignment
- 7.9.17 Relay Code Assignment using Standard Method
- 7.9.18 Relay Code Assignment using Search Method
- 7.9.19 PIN Code Length/Factory Default Settings
- 7.9.20 Replacing a Lost Programming Code
- 7.9.21 Exiting Secure Mode if Normal/Secure Code was Lost
- A. Declaration of Conformity
- B. Limited Warranty
Technical Specifications
AYC-x6355 (Rev. A) Installation and User Manual 11
2. Technical Specifications
Electrical Characteristics
Power Supply Type
Regulated
Operating Voltage Range
8 to 16 VDC
Current @ 12 V
AYC-H/M6355: Standby: 120 mA, max: 160 mA
AYC-Q6355: Standby: 145 mA, max: 200 mA
Read Range*
AYC-H/M6355: 9 cm (3.5 in.)
AYC-Q6355: 5 cm (2.5 in.)
Green LED Control**
Dry Contact, N.O.
Red LED Control**
Dry Contact, N.O.
Buzzer Control**
Dry Contact, N.O.
Tamper Output**
Open collector, active low, max. sink current
16 mA
Maximum Cable Distance
to Controller
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1,200 m (4,000 ft) with 2x2 18-
AWG twisted shielded cable
Environmental Characteristics
Operating Temp. Range
-35°C to 66°C (-31°F to 150°F)
Operating Humidity
Range
0 to 95% (non-condensing)
Outdoor Usage
Weather-resistant, UV-resistant, epoxy-potted,
suitable for indoor and outdoor use
* Measured using a Rosslare MIFARE Classic EV1 (ISO Card). Read range with
other credential technologies may vary. Range also depends on electrical
environment and proximity to metal.
** Control Lines are factory programmable and can be custom configured upon
request.