38 AYC-Ex5 and AYC-T65 Installation and Programming Manual
6.4 Door Alarms
Door alarms can be generated by connecting the Auxiliary Input to a
Door Position Switch. Either Door-Forced or Door-Ajar conditions are
supported, as well as, a configurable delay timer for each alarm type.
Only one door alarm is enabled at any one time. Door alarms may
activate auxiliary output and siren depending on the auxiliary settings.
6.5 Internal Case and Back Tamper
If the unit is forcibly opened or it is removed from the wall, a tamper
event is triggered. A tamper output opens sending a to the connected
Alarm system (purple wire) the event closes when the tamper is closed
(case is re-closed or re-attached to the wall).
The tamper event can also activate the auxiliary output if the
controller is in Auxiliary Mode 3 (see Table 5).
6.6 Lockout Feature (Keypad Tamper)
If the controller is presented with wrong codes, consecutively several
times the unit goes into lockout mode.
When a lockout occurs, the controller keypad is de-activated so no
codes can be entered until the set lockout period expires.
During Lockout, Mode LED is Off, Door LED flashes red, and the
controller beeps every two seconds
.
6.7 Request to Exit (REX) Function
The REX button is connected to Rosslare’s secure application
appurtenance. The REX button must be located inside the premises to
be secured and is used to open the door without the use of a PIN
code. It is usually located in a convenient location, such as inside the
door or at a receptionist's desk. The function of the REX button
depends on whether the Lock Strike Relay is programmed for Fail Safe
Operation or Fail Secure Operation.
Fail Secure OperationFrom the moment the REX button is
pressed, the door is unlocked until the Lock Strike Release Time