User manual
MUX-6258-A Series User Manual (Iss. 04) DashBoard Menus • 4–11
Embedded
Input Audio -
Group #
Group not present
Selected*
Signal Status field reports when a group is
not present on the input
Cleared Disables the alarm
Channel # Silent
Selected*
Signal Status field reports when the
specified channel is detected as silent
Cleared Disables the alarm
AES Inputs -
AES #
Input not present
Selected*
Signal Status field reports when the source
for the specified input is not present
Cleared Disables the alarm
Channel # Silent
Selected*
Signal Status field reports when the
specified channel is detected as silent
Cleared Disables the alarm
Embedded
Outputs -
Group #
Source Missing
Selected*
Embedded Audio Status field reports
when the selected source is not present or
is silent
Cleared Disables the alarm
Source Async
Selected*
Embedded Audio Status field reports
when the selected source is asynchronous
to the input video
Cleared Disables the alarm
Backup Source
Missing
Selected*
An alarm is displayed when the selected
Backup Source is not present or is silent
Cleared Disables the alarm
Backup Source Async
Selected*
An alarm is displayed when the selected
Backup Source is not synchronous to the
input video
Cleared Disables the alarm
SD 24Bit
Selected*
Audio Status field displays an alarm when
the selected configuration would embed 4
groups of 24bit audio in an SD output.
Group 4 is down-sampled to 20bit audio.
Cleared Disables the alarm
All Alarms Set Enables all alarms
All Alarms Clear Disables all alarms
Table 4.8 Alarms Menu Items