Operator`s manual
8–6 • Specifications CrossOver 6 / 12 User Manual (v4.0)
Key Invert Keyer 0x44 Turning OFF results in a protocol error.
Key Mask Keyer 0x45 Turning OFF results in a protocol error.
Memory Mode Toggle
— 0x47 Toggles between memory and pattern
modes.
Next Trans Is Bkgd — 0x48 Turning OFF results in a protocol error.
Next Trans Is Key 1 — 0x49 Turning OFF results in a protocol error.
Cut MLE 0x4A Turning OFF results in a protocol error.
Key Selfkey Keyer 0x4C Turning OFF results in a protocol error.
Key Autokey Keyer 0x4D Turning OFF results in a protocol error.
Key Chromakey Keyer 0x4E Turning OFF results in a protocol error.
Editor Enable
— 0x4F Editor control is always enabled.
Turning OFF results in a protocol error.
Keyer Active Keyer 0x52
Table 8.6 GVG100 Supported Buttons
Name MLE/Keyer Byte code Notes
Program Bus 0-9 MLE 0x00-0x09
Autotrans MLE 0x0B
Key Trans Keyer 0x0C DSKs
Key Cut Keyer 0x0D DSKs
Wipe Trans MLE 0x0E
Dissolve Trans MLE 0x0F
Preset Bus 0-9 MLE 0x10-0x19
Aspect MLE 0x1B Always on. Button press has no effect.
Positioner On — 0x1C Always on. Button press has no effect.
Reverse Wipe
MLE 0x1D Doubles as memory store/recall toggle
when in memory mode
Dsk Preview
— 0x1E Always true. All Keyers show on
preview.
Fade To Black 0x1F
Key Bus 0-9 Keyer 0x20-0x29
Key Video Fill Keyer 0x2F Always true.
Wipe Type MLE 0x30-0x39
Key Invert Keyer 0x40 DSKs
Key Mask Keyer 0x41 DSKs
Key Autokey Keyer 0x42 DSKs
Key Selfkey Keyer 0x43 DSKs
Key Invert Keyer 0x44
Table 8.5 GVG100 Supported Lamps
Name MLE/Keyer Byte Code Notes