Operator`s manual
CrossOver 6 / 12 User Manual (v4.0) Advanced Operation • 4–7
To create an FTP connection to your switcher
from Windows XP Professional, or Windows 7:
1. On the taskbar, click that Start button.
2. Select All Programs > Accessories >
Windows Explorer.
3. In the Windows Explorer address bar, type
ftp://<ip_addr>
• where <ip_addr> is the IP address of your
switcher).
4. Enter the following when prompted for a user
name and password:
Note:
• The user and xpression accounts also have
access to the USB drive if one is plugged into your
switcher.
Live Edit Decision Lists (EDL)
Edit Decision Lists are files used by non-linear
editing (NLE) suites to aid in post-production. Your
switcher can capture EDL data in a file that you load
into your NLE suite.
Configuring Live EDL Behavior
You can configure your switcher to trigger multiple
GPI outputs at the start, end, or both of EDL data
capture. You can also set a pre-delay for each GPI
output. EDL data capture does not begin until the
highest pre-delay has passed. This is useful when the
switcher needs to wait for external equipment to
become ready. The example below shows the effects
of various triggering and pre-delay settings.
Figure 4.1 Live EDL Timeline
1. EDL capture is manually started. GPI output 2 is
triggered.
2. 4 frames later, GPI output 1 is triggered.
3. 16 frames after EDL capture is manually
triggered, the switcher begins capturing EDL
data.
4. EDL capture is manually stopped. GPI output 2
and 3 are triggered.
To configure Live EDL behavior:
1. Press MENU.
2. Press the SYSTEM Wipe Pattern button.
3. Press NEXT until LivEDL Config is
displayed.
4. Press the LiveEDL Config knob to display
the EDL Configuration menu.
5. Use the GPO knob to select a GPI output.
You can choose from any GPI bank and pin that
has been configured as a GPI output.
6. Use the Triggr knob to select when the GPI
output is triggered. You can choose from the
following:
• Off — The GPI output is not triggered.
• Start — The GPI output is triggered at the
start of EDL data capture.
• Stop — The GPI output is triggered at the
end of EDL data capture.
• Both — The GPI output is triggered at both
the start and end of EDL data capture.
7. If you selected Start or Both in step 6, use the
PreDly knob to specify the number of
frames the switcher delays after the GPI output
is triggered before EDL capture begins.
Table 4.2 FTP Account Information
User Name Password Account Type
xpressio
n
password
Use for accessing
Media-Store storage.
liveedl password
Use for accessing Live
EDL storage.
user password General storage access
Table 4.3 Live EDL GPI Output Triggers
GPI
Output
Triggered On Pre-Delay (Frames)
1
Start 12
2
Both 16
3
Stop —
1 42 3
16
12
MENU