Product manual

A memory attribute does not need to be stored in the
memory to be recalled.
To Set the Program Bus Source Attribute
1.
Press RECALL > NEXT > NEXT.
2.
Use the Attrib knob to select PGMBus.
3.
Use the Value knob to select how the sources
selected on the program bus are recalled.
Memory — settings come from the memory
being recalled
NoRcl — sources are not recalled on the
program bus
Recall — sources are recalled on the
program bus (default)
To Set the Preset Bus Source Attribute
1.
Press RECALL > NEXT > NEXT.
2.
Use the Attrib knob to select PSTBus.
3.
Use the Value knob to select how the sources
selected on the preset bus are recalled.
Memory — settings come from the memory
being recalled
NoRcl — sources are not recalled on the
preset bus
Recall — sources are recalled on the preset
bus (default)
To Set the Transition Type Attribute
1.
Press RECALL > NEXT > NEXT.
2.
Use the Attrib knob to select Trans.
3.
Use the Value knob to select how the next
transition type and parameters are recalled.
Memory — settings come from the memory
being recalled
NoRcl — transition selections are not
recalled
Recall — transition selections are recalled
(default)
To Set the Next Transition Attribute
1.
Press RECALL > NEXT > NEXT.
2.
Use the Attrib knob to select NextTr.
3.
Use the Value knob to select how the next
transition area is recalled.
Memory — settings come from the memory
being recalled
NoRcl — next transition area settings are
not recalled
Recall — next transition are settings are
recalled (default)
To Set the Run Auto Trans Attribute
1.
Press RECALL > NEXT > NEXT.
2.
Use the Attrib knob to select RnAuto.
3.
Use the Value knob to select whether a
transition is performed after the memory is
recalled.
Memory — settings come from the memory
being recalled
NoRun — a transition is not performed after
the memory is recalled (default)
Run — a transition is performed after the
memory is recalled
To Set the Shared Pattern Generator Attribute
1.
Press RECALL > NEXT > NEXT.
2.
Use the Attrib knob to select SrdPat.
3.
Use the Value knob to select whether the
settings for the shared Key Mask/Wash pattern
generator is recalled.
Memory — settings come from the memory
being recalled
NoRcl — shared pattern generator settings
are not recalled
Recall — shared pattern generator settings
are recalled (default)
To Set the Key Bus Sources Attribute
1.
Press RECALL > NEXT > NEXT.
2.
Use the Attrib knob to select KeyBus.
3.
Use the Key knob to select the keyer you want
to use the attribute for.
4.
Use the Value knob to select whether sources
selected on the selected key bus are recalled.
Memory — settings come from the memory
being recalled
NoRcl — sources are not recalled on the key
bus
Carbonite Operation Manual (v6.1) — Memory Functions • 35