User manual
ADC-8733A User Manual (Iss. 02B) Menus • 4–5
Timing Menus
Table 4.3 summarizes the Timing Menu options available in DashBoard for the ADC-8733A.
Setup
Setup
m
Off Disables the NTSC setup removal
On Enables the NTSC setup removal
Edit Permission
Unlocked
All menu options are unlocked and can be
edited.
Locked
All menu items, except this one, are
locked and read-only.
Factory Defaults Reset Resets all parameters to factory defaults.
Licensable Features
Indicates if the software key for any
licensable features is installed.
a. This option is only available for 525-line standards.
Table 4.3 Timing Menu Items
Tab Title Item Parameters Description
Timing
Reference
m
Frame Ref 2
The reference source is the analog
reference connected to the frame REF 2
port
Frame Ref 1
The reference source is the analog
reference connected to the frame REF 1
port
BNC 8
The reference source is the analog
reference connected to BNC 8
Input Timing
m
Frame Ref 2
The timing source is the analog signal
connected to the frame REF 2 port
Frame Ref 1
The timing source is the analog signal
connected to the frame REF 1 port
BNC 8
The timing source is the analog signal
connected to BNC 8
Y/G
The timing source is the analog signal
connected to BNC 1
Timing Mode
m
Line Delay Output timing is based on the input timing
Line Sync Output timing is based on the reference
Frame Delay
a
Output timing is based on the input timing
Frame Sync
a
Output timing is based on the reference
Horizontal Delay
m
0 to 1715
b
Adjusts the horizontal delay
0 to 1727
c
Table 4.2 Setup Menu Items
Tab Title Item Parameters Description