User manual
ADC-8733A User Manual (Iss. 02B) Menus • 4–3
DashBoard Menus for the ADC-8733A
This section briefly summarizes the menus, items, and parameters available from the DashBoard
Control System™ for the ADC-8733A. Parameters marked with an asterisk (*) are the factory
default values. Parameters marked with
m
an are values stored in the non-volatile memory.
The DashBoard Control System™ enables you to monitor and control openGear frames and cards
from a computer. DashBoard communicates with other cards in the DFR-8300 series frame
through the Network Controller Card.
Status Tab
Table 4.1 summarizes the Status tab parameters available in DashBoard for the ADC-8733A.
The Status tabs provide read-only information such as software revision issue, fan door status,
and power consumption.
Note — The ADC-8733A defaults with Edit Permissions set to Locked.
Table 4.1 Status Tab Items
Tab Title Item Parameters Description
Product
(Read-only)
Product ADC-8733A
Supplier Ross Video Ltd.
Board Rev ## Indicates the board revision level
Serial Number ###### Indicates the card serial number
Software Rev ##.## Indicates the software version
Firmware Rev #.### Indicates the firmware version
Hardware
(Read-only)
HW Status
Green - OK Normal operation; no hardware errors
Yellow - Check I/O Module
Card is connected to a rear module not
supported by the AAM-8581
a
Red - FPGA load invalid
The card failed to load the FPGA
firmware
Red - Income I/O Module
Card is connected to an incompatible rear
module
Voltage (mV) # Supply Voltage
Current (mA) # Current consumption of card
Rear Module # Type of rear module in the slot
CPU Headroom # Processing power available
RAM Available #/## On-board processing memory available
EE Bank # Storage count