User manual
Bank C-3: H Reset
Use the following steps to reset just the H Delay value to 0 (zero). This function is particularly useful
if your adjustment range is far off the mark, or if you simply want to quickly return to zero.
1. Select Bank C, and rotate Function Select to position 3.
2. Reset H Delay as required:
• Toggle Mode Select up to reset H Delay to 0.
Bank Function Select Mode Select Heads-Up Display Label Default
C 3
+ Zero
- No action
H RESET ZERO N/A
Bank C-4: V Delay
Use the following steps to adjust the output’s V Delay:
1. Select Bank C, and rotate Function Select to position 4.
2. Increase or decrease the V Delay as required:
• Toggle Mode Select up to increase V Delay by one line, and wrap around
from the maximum to 0 if necessary.
• Hold Mode Select up to increase V Delay continuously.
• Toggle Mode Select down to decrease V Delay by one line, and wrap
around from 0 to the maximum if necessary.
• Hold Mode Select down to decrease V Delay continuously.
Bank Function Select Mode Select Heads-Up Display Label Default
C 4
+ Increase
- Decrease
V DELAY (#) 0
Bank C-5: V Reset
Use the following steps to reset just the V Delay value to 0 (zero).
1. Select Bank C, and rotate Function Select to position 5.
2. Reset V Delay as required:
• Toggle Mode Select up to reset V Delay to 0.
Bank Function Select Mode Select Heads-Up Display Label Default
C 5
+ Zero
- No action
V RESET ZERO N/A
ADC-8032B User Manual (Iss. 02B) Using Banks • 4-19