Bank C-1: Timing Mode
Use the following steps to set the timing mode:
1. Select Bank C, and rotate Function Select to position 1.
2. Select the desired timing mode according to the following table.
Toggle Mode Select up to advance up the list.
Toggle Mode Select down to descend down the list.
Bank Function Select Mode Select Heads-Up Display Label Default
C 1
+ Frame Sync *
Frame Delay *
Line Sync
- Line Delay
TIME MODE FS
FD
LS
LD
LS
(FS on S
models)
* Indicates ADC-8032B-S only
Bank C-2: H Delay
Use the following steps to adjust the output’s H Delay:
1. Select Bank C, and rotate Function Select to position 2.
2. Increase or decrease the H Delay as required:
Toggle Mode Select up to increase H Delay by half a pixel (one 27MHz-
clock period) with each toggle.
Hold Mode Select up to increase H Delay continuously.
Toggle Mode Select down to decrease H Delay by half a pixel (one
27MHz-clock period) with each toggle.
Hold Mode Select down to decrease H Delay continuously.
Bank Function Select Mode Select Heads-Up Display Label Default
C 2
+ Increase
- Decrease
H DELAY (#) 0
Please note the following important points regarding H Delay:
If you cross over the maximum H Delay, the value returns to 0 (zero) and the V
Delay value increments by 1.
Crossing the minimum delay returns the H Delay value to 1715 (NTSC or PAL-M)
or 1725 (PAL-B or PAL-N) and decrements the V Delay value by 1.
Note
Crossing from 0 to maximum or from maximum to 0 will affect
the V Delay setting in Bank C-4.
Sub-pixel timing adjustments can be made using the RV1 Fine Phase Adjust
potentiometer on the front edge of the card. Turning the pot clockwise increases
delay, whereas turning it counter-clockwise decreases the delay. The range is
approximately ±20 ns, which is slightly longer than the step size of the H Delay
function.
4-18 Using Banks ADC-8032B User Manual (Iss. 02B)