User manual
Bank B-6: V Bit Lock
Use the following steps to force the V bit for 10 or 20 lines.
Note
V Bit Lock is only available in NTSC. In PAL-B, PAL-M, and
PAL-N, V Bit Lock cannot be changed.
V-BIT LOCK cannot be changed in 625
1. Select Bank B, and rotate Function Select to position 6.
2. Choose the desired line:
• Toggle Mode Select up to have the V bit set to line 20.
• Toggle Mode Select down to have the V bit set to line 10.
Bank Function Select Mode Select Heads-Up Display Label Default
B 6
+ Line 20
- Line 10
V BIT LOCK 20
10
20
Using Bank C Functions
The following topics are discussed in this section:
• Timing Mode
• H Delay
• H Reset
• V Delay
• V Reset
• Set Minimum Delay
• Freeze Mode
• Forced Freeze
• Input Loss Mode
• Hotswitch Mode
• Forced Black
• Forced Monochrome
Bank C-1: Timing Mode
The following topics are discussed in this section:
• About the Timing Mode
• Timing Mode Summary
• Bank C-1: Timing Mode Procedure
About the Timing Modes
The ADC-8032B and ADC-8032B-S offer two sets of timing modes; Line Delay/Sync and Frame
Delay/Sync.
4-14 • Using Banks ADC-8032B User Manual (Iss. 02B)