User manual

Bank A-E: Factory Defaults
This function allows you to return all controls to their default values, or simply the six “Proc Amp”
controls by themselves. Use the following steps to select factory default values:
1. Select Bank A, and rotate Function Select to position E.
2. Select the desired default settings:
Hold Mode Select up to reset all adjustments to their default values.
Hold Mode Select down to reset the six “Proc Amp” adjustments to their
default values (Video Gain, Black Level Offset, Chroma Gain, Hue, C
B
Gain, and AGC).
Bank Function Select Mode Select Heads-Up Display Label Default
A E
+ (h) Reset All
- (h) Reset Proc Amp
DEFAULT ALL RST
PROC RST
N/A
Bank A-F: Lock/Unlock Switch Access
The Switch Access function allows you to lock or unlock user access to all adjustment parameters.
The “lock” function should be performed after installation to secure all settings, and to prevent anyone
from accidentally changing the settings. Note the following rules:
When access is locked, no adjustments can be made and the Heads-Up Display is
automatically turned off.
When you unlock switch access and you wish to use the Heads-Up display again,
you must manually enable it (Bank A, position 1).
Use the following steps to lock or unlock switch access:
1. Select Bank A, and rotate Function Select to position F.
2. Choose the desired access mode:
Toggle Mode Select up to lock switch access. Adjustments cannot be
made, and the display is disabled. The ACCESS LED is off.
Hold Mode Select down for one second to unlock switch access.
Adjustments can now be made. The ACCESS LED is on.
Bank Function Select Mode Select Heads-Up Display Label Default
A F
+ Locked
- (h) Unlocked
ACCESS LOCKED
UNLOCKED
LOCKED
ADC-8032B User Manual (Iss. 02B) Using Banks 4-11