User manual
Bank C Function Table
Table 5. Function Select: Bank C Function Table
Function
Select
Function
Mode Select
Options
Heads Up Display On-
Screen Label and Value
Default
Value
0 Bank Select
+ A
B
- C
BANK A
B
C
A
1
Timing Mode
m
+ Frame Sync*
Frame Delay*
Line Sync
- Line Delay
TIME MODE FS
FD
LS
LD
LS
(FS on S
model)
2
H Delay
m
+ Increase
- Decrease
H DELAY (####)
0
3 H Reset
+ Zero
- No action
H RESET ZERO
N/A
4
V Delay
m
+ Increase
- Decrease
V DELAY (#)
0
5 V Reset
+ Zero
- No action
V RESET ZERO
N/A
6 Set Min. Delay
+ Zero
- No action
MIN DEL ZERO
N/A
7
Input Mode
m
+ VTR input
- Standard input
IN MODE VTR
STAND
STAND
8
Freeze Mode
m
,
**
+ Frame
Field 2
- Field 1
FRZ MODE FRAME
FLD 2
FLD 1
FLD 1
9 Forced Freeze
+ Freeze**
- Pass Through
FREEZE FORCE
PASS
PASS
A
Input Loss Mode
m
+ Freeze**
No Output
- Black
IN LOSS FREEZE
NO OUTPUT
BLACK
BLACK
B
Hotswitch Mode
m
+ Freeze**
- Black
Off
HOTSW MD FREEZE
BLACK
OFF
OFF
C Forced Black
+ (h) On
- (h) Off
FRCD BLK ON
OFF
OFF
D Forced Mono
+ (h) On
- (h) Off
FRCD MONO ON
OFF
OFF
E N/A
F N/A
Note
Functions, as listed in the Function column as being stored in memory, always power up in the last
known state. All other items, however, power up in the default state, regardless of their previous state.
* Only available on ADC-8032B-S.
** When Freeze mode is activated the freeze is determined by C-8 (Freeze Mode).
m
Stored in non-volatile memory
ADC-8032B User Manual (Iss. 02B) Using Banks • 4-5