Function Select Switch – SW1
The (SW1) Function Select switch is a 16-position rotary switch used to select functions such as
proc amp controls and timing adjustment menu items. The SW1 switch works in conjunction with
the SW2 toggle switch; first, the function category is selected with SW1, and then the SW2 toggle
switch is used to select modes or configuration settings within that function selection. See Chapter
4, “Using Banks” for complete details.
Mode Select Switch – SW2
The (SW2) Mode Select switch is used to enable, disable, and select specific ADC-8032B
functional modes, or configurations, within the operational function menu (selected first with the
SW1 Function Select switch). The Mode Select switch is a 3-position momentary toggle switch
with an automatic spring-return to the center position.
There are two methods of toggling SW2 to select basic and advanced level menu items:
Single toggle to select single options
Hold toggle to scroll through multiple values or options
Toggling the switch for menu selection is made according to two basic menu design categories:
menu selections utilizing a scrolling wrap-around style of selection (from last
menu item directly back to first menu item)
menu selections utilizing a bi-directional style of selection (with upper and
lower range limits)
Fine Phase Adjust Potentiometer
The RV2 Fine Phase Adjust potentiometer adjusts the board’s output delay in sub-pixel
increments, with a range of 0 (zero) to approximately 40ns.
3-2 User Controls ADC-8032B User Manual (Iss. 02B)