BULLETIN 600T ISO Valves and Serial Bus Communication with Turck Modular I/O System Premium Pneumatic Controls Since 1921 EtherNet/IPTM ControlNetTM PROFIBUS® DeviceNetTM CANopen
ROSS' website is the most complete and up-to-date source for product research and documentation. Search results produce downloadable documentation or request for quote (RFQ). Additional product information or CAD files are easily requested from Technical Service Team. Additional information such as certifications, links and associations is also available.
Table of Contents Standard Definitions........................................................................................................................................ 4 Serial Bus Systems......................................................................................................................................... 5 ISO Size 00 & 0 Valves, Series W66 - Ordering Code ...................................................................................
Standard Definitions 15407-1: Drop-cord Standards for Size 0 (26mm) & Size 00 (18mm) Wide Valves 15407-2: Plug-in Standards for Size 0 (26mm) & Size 00 (18mm) Wide Valves 5599-1: Drop-cord Standards for Sizes 1, 2, 3 5599-2: Plug-in Standards for Size 1, 2, 3 ! WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
www.rosscontrols.
ISO Size 00 & 0 Valves Series W66 HOW TO ORDER (Choose your options (in red) to configure your valve model number.
Plug-in, Series W66 (15407-2) Size 00 (18mm) & Size 0 (26mm) 5/2 Valves – Single Solenoid Pilot ISO Port Valve Model Size Size Number* 4 2 00 0 Sol. 14 51 3 1/8 1/4 Avg. Dimensions inches (mm) CV Length Width Height W6676A0401 W6676A1401 0.55 1.1 Weight lb (kg) 4.43 (113) 0.72 (18) 1.98 (50) 5.10 (130) 1.02 (26) 1.98 (50) * Sub-base not included. See page 10-17 for sub-bases, manifolds and accessories.
Spool and Sleeve Valves for ISO Sub-Bases (5599/II) Series W65 5/2 Valves – Single Solenoid Pilot Controlled, Spring Return ISO Port Valve Model Size Size Number* 4 1 2 3 2 14 5 1 3 1/4 - 3/8 3/8 - 1/2 1/2 - 3/4 W6576A2401 W6576A3401 W6576A4401 Avg. Dimensions inches (mm) CV Length Width Height 1.0 2.3 3.4 6.3 (161) 7.3 (186) 8.5 (216) 1.6 (41) 2.1 (52) 2.6 (67) Weight lb (kg) 2.7 (69) 2.8 (71) 3.1 (78) 1.5 (0.7) 2.0 (1.0) 3.5 (1.6) * Sub-base not included.
Spool and Sleeve Valves for ISO Sub-Bases (5599/II) Series W65 5/2 Valves – Single Pressure Controlled, Spring Return ISO Port Valve Model Size Size Number* 1 2 3 1/4 - 3/8 3/8 - 1/2 1/2 - 3/4 Avg. Dimensions inches (mm) CV A B C W6556A2411 W6556A3411 W6556A4411 1.0 2.3 3.4 4.8 (121) 5.8 (148) 7.0 (178) 1.6 (41) 2.1 (52) 2.6 (67) Weight lb (kg) 2.7 (69) 2.8 (71) 3.1 (78) 0.8 (0.4) 1.5 (0.7) 3.0 (1.4) * Sub-base not included.
Plug-in, Series W66 (15407-2) Size 00 & 0 Manifold / Sub-Base Kits HOW TO ORDER (Choose your options (in red) to configure your valve model number.
Plug-in, Series W65 (5599-2) Size 1, 2, & 3 Manifold / Sub-Base Kits HOW TO ORDER (Choose your options (in red) to configure your valve model number.) R PS4011 55 M C Basic Series Size 1 PS4011 Size 2 PS4111 Size 3 PS4211 P Enclosures / Lead Length J† Circuit Board, Single Address M† Circuit Board, Double Address † Not Available with Subbase Kits.
End Plate Kits, Series W66 & W65 Series W66 Size 00 & 0 End Plate Kits HOW TO ORDER (Choose your options (in red) to configure your valve model number.) R PS56 20 T1 0 P Basic Series Thread Type ISO 15407, Size 00 (18mm) & Size 0 (26mm) PS56 0 NPT 1 BSPP “G” End Plate Kit Type End Plate, Collective Wiring 20 Options T1 16 Outputs T2 32 Outputs Series W65 Size 1, 2, & 3 End Plate Kits HOW TO ORDER (Choose your options (in red) to configure your valve model number.
Accessories Blank Stations, Port Isolation, Gaskets Blank Station Kits Size Kit Number 15407-2 Size Kit Number 5599 Size 00 RPS5634P Size 1 RPS4034CP Size 0 RPS5534P Size 2 RPS4134CP Size 3 RPS4234CP Kit includes: Blank Station Plate, Gasket, and Mounting Bolts. 15407-2 5599 Kit includes: Blank Station Plate, Gasket, and Mounting Bolts.
Accessories Interposed Regulators Size 00 & 0 Features: HOW TO ORDER (Choose your options (in red) to configure your valve model number.
Accessories Gauge Adapter Kit Description Part Number Included with all Size 00 Regulators. Both kits are required on all Size 0 & 00 Regulators when the Regulator is on the last Station on the Right (14) End.
Service & Repair Kits Series W65 Replacement Pilot Assembly & Coil Description Model Number Pilot Assembly 1149C79 Coil 334B33 Kit Number RPS5612P Size 0 RPS5512P Size 1 RPS4012P Size 2 RPS4112P Size 3 RPS4212P Standard Blocked #1 Port Blocked #1, 3, 5 Ports Blocked #3, 5 Ports RPS561AP RPS561BP RPS561CP RPS561DP Size 1 RPS4013P — — — Size 2 RPS4113P — — — Size 3 RPS4213P — — — Size 00 Size 0 Manifold Hardware Kits Size 00 15407-2 Size Specify Voltage and Hz when ord
Service & Repair Kits Regulator Conversion Kits Valve Size Size 1 Regulator Spring Range Kits Manual Bonnet Assembly (w/o Spring) Air Pilot Bonnet Assembly Independent By-Pass Plate Spring Range Size 1 Size 2 & 3 0 to 30 PSIG RPS4050030P RPS4150030BP RPS4045BP RPS4047BP RPS4048BP 2 to 60 PSIG RPS4050060P RPS4150060BP 5 to125 PSIG RPS4050125P RPS4150125BP RPS4145BP RPS4147BP RPS4148BP Size 2 Quantity 1 Size 3 Quantity 1 Technical Information Temperature Rating Response Time** (ms)
TURCK Modular Industrial I/O System BL 67 The BL67 Solution BL67 Power Distribution BL67 combines all the flexibility of an in-the-cabinet PLC I/O system with modularity, ruggedness and connectorization. Power Overview BL67 complements the AIM™, BL20 and piconet® product families to meet the needs of unique applications, such as small machine or conveyor systems requiring IP 67 protection. The BL67 Concept The BL67 modular concept is a very flexible approach to connectorized I/O.
TURCK Modular Industrial I/O System BL 67 Applying Power to BL67 PROFIBUS® , Ethernet and CANopen System VMB(5V) IMB(5V) System Power Isolation 4A Field Power VMB(24V) IMB(24V) 4A II II IO IO VI VO VI VO VI, VO, VMB from Power on Gateway IMB(5V) < 1.5A < 4A (protected) II IO < 8A Isolation of Field Power VI, VO VMB = Module Bus Power VI = Input Power VO = Output Power A power feeder module provides a new isolated segment for all modules to its right.
TURCK Modular Industrial I/O System BL 67 Environmental Conditions General Environmental Intended Application Environments • BL67 does not need an enclosure • Mount directly on machine or conveyor • Rugged design provides protection against dirt, dust and liquids Not intended for These Environments Potential isolation Via optocoupler Operating temperature 32° to +131°F (0° to +55°C) Storage temperature -13° to +185°F (-25° to +85°C) Relative humidity 5 to 95% (indoor), noncondensing Vibration 1
TURCK Modular Industrial I/O System BL 67 Modular I/O • DeviceNet Gateway Electrical: • Fieldbus Independent Configuration IP 67 Protection • Various I/O Styles BL67-GW-DN • Operating Current: <600 mA from VMB • Supply Current: <8 A to I/O (from DeviceNet) • Backplane Current: <1.
TURCK Modular Industrial I/O System BL 67 • Modular I/O ModBus TCP/IP Ethernet Gateways BL67-GW-EN BL67-PG-EN Ethernet IP Ethernet Gateways BL67-GW-EN-IP BL67-PG-EN-IP Electrical: • • • • • Fieldbus Independent Configuration IP 67 Protection • Various I/O Styles Operating Current: <600 mA from VMB Input Supply Current: <4 A (from VI) Output Supply Current: <8 A (from VO) Backplane Current: <1.
TURCK Modular Industrial I/O System BL 67 • Modular I/O Profinet Ethernet Gateways Electrical: • • • • • Fieldbus Independent Configuration • IP 67 Protection Various I/O Styles BL67-GW-EN-PN Operating Current: <600 mA from VMB Input Supply Current: <4 A (from VI) Output Supply Current: <8 A (from VO) Backplane Current: <1.
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration IP 67 Protection • Various I/O Styles BL67-GW-DPV1 BL67-PG-DP PROFIBUS-DP Gateway • Operating Current: <50 mA from VI • Supply Current: <10 A to I/O (from VI and VO) • Backplane Current: <1.
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration CANopen Gateway • IP 67 Protection Various I/O Styles BL67-GW-CO • Operating Current: <600 mA from VMB • Supply Current: <8 A to I/O (from DeviceNet) • Backplane Current: <1.
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration CANopen Gateway Electrical: • IP 67 Protection • Various I/O Styles BL67-GW-CO-T • Operating Current: <600 mA from VMB • Supply Current: <8 A to I/O (from DeviceNet) • Backplane Current: <1.
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration • IP 67 Protection Various I/O Styles BL67-4DI-P BL67-4DI-N 4 Discrete Input Modules Electrical: • Operating Current: <30 mA from VMB <40 mA from VI (...-P) <1 mA from VI (...
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration • IP 67 Protection Various I/O Styles BL67-8DI-P BL67-8DI-N 8 Discrete Input Modules Electrical: • Operating Current: <30 mA from VMB <40 mA from VI (...-P) <1 mA from VI (...
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration 4 Discrete Output Modules • IP 67 Protection Various I/O Styles BL67-4DO-0.5A-P Electrical: • Operating Current: <30 mA from VMB <100 mA from VO • Output Current: <0.
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration IP 67 Protection • Various I/O Styles BL67-4DO-2A-P BL67-4DO-2A-N 4 Discrete Output Modules Electrical: • Operating Current: <30 mA from VMB <100 mA from VO • Output Current: <2 A per output from VO Power Distribution: • Inputs: VO • Logic: VMB and VO Material: • Connectors: Nickel-plated brass • Housing: PC-VO (Lexan) Shown with BL67-B-2M12 base Diagnostics (Logical): • Diagnostic informatio
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration 8 Discrete Output Modules • IP 67 Protection Various I/O Styles BL67-8DO-0.5A-P Electrical: • Operating Current: <30 mA from VMB <100 mA from VO • Output Current: <0.
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration 16 Discrete Output Modules • IP 67 Protection Various I/O Styles BL67-16DO-0.1A-P Electrical: • Operating Current: <30 mA from VMB <100 mA from VO • Output Current: <0.
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration Deluxe 4 Discrete Input Modules IP 67 Protection • Various I/O Styles BL67-4DI-PD Electrical: • Operating Current: <30 mA from VMB <100 mA from VI Power Distribution: • Inputs: VI • Logic: VMB and VI Shown with BL67-B-4M8 base Material: • Connectors: Nickel-plated brass • Housing: PC-VO (Lexan) Diagnostics (Logical): • Diagnostic information available through the fieldbus gateway Diagnostics (Ph
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration Deluxe 8 Discrete Input Modules • • IP 67 Protection Various I/O Styles BL67-8DI-PD Electrical: • Operating Current: <30 mA from VMB <100 mA from VI Power Distribution: • Inputs: VI • Logic: VMB and VI Material: • Connectors: Nickel-plated brass • Housing: PC-VO (Lexan) Shown with BL67-B-4M12 base Diagnostics (Logical): • Diagnostic information available through the fieldbus gateway Diagnostics (P
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration • IP 67 Protection Various I/O Styles BL67-8XSG-P BL67-8XSG-PD Discrete Input/Output Module Electrical: • Operating Current: <30 mA from VMB <100 mA from VO • Output Current: <0.
TURCK Modular Industrial I/O System BL 67 • Modular I/O • Fieldbus Independent Configuration Deluxe 4 Discrete Input 4 Discrete Output Module • IP 67 Protection Various I/O Styles BL67-4DI4DO-PD Electrical: • Operating Current: <30 mA from VMB <100 mA from VO • Output Current: <0.
TURCK Modular Industrial I/O System BL 67 Modular I/O • • Fieldbus Independent Configuration CANopen Interface Module IP 67 Protection • Various I/O Styles BL67-1CVI Electrical: • Operating Current: <30 mA from VMB (SSI) <50 mA from V (all) <100 mA from V supply Power Distribution: • Inputs: VI • Logic: VMB and V Shown with BL67-B-4M12 base Material: • Connectors: Nickel-plated brass • Housing: PC-VO (Lexan) Diagnostics (Logical): • Diagnostic information available through the field
TURCK Modular Industrial I/O System BL 67 Modular I/O • • Fieldbus Independent Configuration Serial Communication Modules • IP 67 Protection Various I/O Styles BL67-1RS485/422 BL67-1RS232 BL67-1SSI Electrical: • Operating Current: <140 mA from VMB (RS232) <60 mA from V MB (RS485/422) <50 mA from V MB (SSI) <50 mA from V (all) Power Distribution: • Inputs: V • Logic: VMB and V Material: • Connectors: Nickel-plated brass • Housing: PC-VO (Lexan) Diagnostics (Logical): • Diagnostic i
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration Serial Communication Modules • • IP 67 Protection Various I/O Styles BL67-1RS485/422 BL67-1RS232 BL67-1SSI Input/Output Connectors Byte Bit 7 In Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 n-1 (Data from modules to the left) n Data Byte 5 (MSB) n+1 Data Byte 4 n+2 Data Byte 3 n+3 Data Byte 2 n+4 Data Byte 1 n+5 n+6 Frame Err HndSh Err HW Prm Failure Err RX_BYTE_ CNT n-1 Bit 4 Bit 3 Bit 2 STOP X
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration • IP 67 Protection • Various I/O Styles BL67-2AI-V BL67-2AI-I BL67-4AI-V/I 2 Analog Input Modules Electrical: • Operating Current: <35 mA from VMB <12 mA from V Power Distribution: • Inputs: VI • Logic: VMB and VI Material: • Connectors: Nickel-plated brass • Housing: PC-VO (Lexan) Diagnostics (Logical): • Diagnostic information available through the fieldbus gateway Diagnostics (Physical): • LED to
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration • • IP 67 Protection Various I/O Styles BL67-2AI-TC BL67-2AI-PT 2 Temperature Input Module Electrical: • Operating Current: <35 mA from VMB (TC) <45 mA from VMB (PT) <30 mA from V (all) Power Distribution: • Inputs: VI • Logic: VMB and VI • Thermocouples Types: B, E, J, K, N, R, S AND T (TC) • RTD Types: PT100, PT200, PT500, PT1000, Ni100, Ni1000 (PT) Material: • Connectors: Nickel-plated
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration • • IP 67 Protection Various I/O Styles BL67-2AO-V BL67-2AO-I 2 Analog Output Modules Electrical: • Operating Current: <60 mA from VMB (V) <40 mA from VMB (I) <50 mA from VI (all) Power Distribution: • Inputs: VI • Logic: VMB and VI Material: • Connectors: Nickel-plated brass • Housing: PC-V0 (Lexan) Diagnostics (Logical): • Diagnostic information available through the fieldbus gateway Diagnosti
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration Power Feeding Module • IP 67 Protection • Various I/O Styles BL67-PF-24VDC Electrical: • Operating Current: <30 mA from VMB • Output Current: <10 A for downstream I/O Power Distribution: • Accepts 24 VDC supply to provide V1 and VO for downstream modules Material: • Connectors: Nickel-plated brass • Housing: PC-V0 (Lexan) Diagnostics (Logical): • Diagnostic information available through the fieldbus
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration • IP 67 Protection • Various I/O Styles Base Modules for BL67 I/O Two eurofast ® Connectors BL67-B-2M12 Two eurofast ® Connectors with Paired I/O BL67-B-2M12-P Base module with two eurofast connectors. When used with 4 input or 4 output modules each connector has 2 I/O points. Base module with two eurofast connectors. Each connector has 2 I/O points, paired so consecutive points are on the same connector.
TURCK Modular Industrial I/O System BL 67 Modular I/O • Fieldbus Independent Configuration • IP 67 Protection • Various I/O Styles Base Modules for BL67 I/O One M23 Connector (12-pin) BL67-B-1M23 BL67-B-1M23-VI Base module with one 12-pin M23 connector. Typically used with 8-output or SSI modules. Base module that allows full 4 A available from V+ pins. One M23 Connector (19-pin) BL67-B-1M23-19 One minifast ® Connector (5-pin) BL67-B-1RSM Base module with one 19-pin M23 connector.
TURCK Products Warranty Terms and Conditions RISK OF LOSS Delivery of the equipment to a common carrier shall constitute delivery to the Purchaser and the risk of loss shall transfer at that time to Purchaser. Should delivery be delayed due to an act or omission on the part of the Purchaser, risk of loss shall transfer to the Purchaser upon notification by TURCK Inc. that the order is complete and ready for shipment. WARRANTIES TURCK INC.
STANDARD CAUTIONS PRE-INSTALLATION or SERVICE 1. Before servicing a valve or other pneumatic component, be sure that all sources of energy are turned off, the entire pneumatic system is shut off and exhausted, and all power sources are locked out (ref: OSHA 1910.147, EN 1037). 2. All ROSS products, including service kits and parts, should be installed and/or serviced only by persons having training and experience with pneumatic equipment.
GLOBAL Reach with a LOCAL Touchsm ROSS CONTROLS ROSS CONTROLS INDIA Pvt. Ltd. Troy, MI., U.S.A. Telephone: + 1-248-764-1800 Fax: + 1-248-764-1850 In the United States: Customer Service: 1-800-GET ROSS (438-7677) Technical Service: 1-888-TEK-ROSS (835-7677) www.rosscontrols.com Chennai, India Telephone: + 91-44-2624-9040 Fax: + 91-44-2625-8730 Email: rossindia@airtelmail.in ROSS SOUTH AMERICA Ltda.