Owner manual

28 © 2012, ROSS CONTROLS
®
. All Rights Reserved.
Accessories
Plug-In
5599-2
Size 2 Shown
• Bothadjustmentscrewsarelocatedonthe
12 end of the unit.
•
Interposed Flow Control mounts with its own
studs, which means the valve uses standard
bolts for mounting.
• InterposedFlowControlisnottobeusedas
a shut off device and is not bubble tight when
needles are fully turned down.
Valve Size
Plug-In
15407-2
Non Plug-In
15407-1
Size 00 (15407-1) RPS5635P RPS5642P
Size 0 (15407-1) RPS5535P RPS5542P
Valve Size
Plug-In
5599-2
Size 1 RPS4035CP
Size 2 RPS4135CP
Size 3 RPS4235CP
Plug-In
15407-1
18mm Shown
Features
AInterposedFlowControlandCommonPort
InterposedRegulatormaybesandwiched
togetheronamanifoldorsubbase.TheInterposed
FlowControlMUSTbelocatedbetweenthemanifold/
subbaseandtheCommonPort
InterposedRegulator.
Interposed Flow Controls