Manual

18 © 2012, ROSS CONTROLS.
All Rights Reserved.
Accessories
Multiple Lock-out Device
Muffl-Air
®
Silencers
ROSS MUFFL-AIR
®
silencers substantially reduce
exhaust noise levels yet produce little back pressure.
Typical impact noise reduction is in the 20–25 dB range.
Pressure Range: 150 psig (10 bar) maximum.
Model Dimensions inches (mm) Weight
Numbers Width Length Thickness lb (kg)
356A30 3.0 (1.4) 3.0 (1.4) 0.4 (.18) 0.3 (0.1)
For use with any ROSS model with L-O-X
®
capability.
Pop-Up Indicator
Pressure Switch
Pneumatic Energy Release Verification Options
Port NPT Model Avg. Dimensions inches (mm) Weight
Size Threads Numbers C
V
A B lb (kg)
1/8 Male 5500A1003 2.0 0.8 (21) 2.2 (56) 0.3 (0.1)
1/4 Male 5500A2003 2.0 0.8 (21) 2.2 (56) 0.3 (0.1)
3/8 Male 5500A3013 2.0 0.8 (21) 2.2 (56) 0.3 (0.1)
3/8 Male 5500A3003 5.7 1.3 (32) 3.8 (96) 0.5 (0.2)
1/2 Male 5500A4003 7.0 1.3 (32) 3.8 (96) 0.5 (0.2)
3/4 Male 5500A5013 7.0 1.3 (32) 3.8 (96) 0.5 (0.2)
3/4 Male 5500A5003 15 2.0 (51) 5.6 (142) 1.5 (0.7)
1 Male 5500A6003 18 2.0 (51) 5.6 (142) 1.5 (0.7)
1¼ Male 5500A7013 18 2.0 (51) 5.6 (142) 1.5 (0.7)
1¼ Female 5500A7001 37 2.5 (64) 5.9 (149) 2.3 (1.0)
1½ Female 5500A8001 38 2.5 (64) 5.9 (149) 2.3 (1.0)
2 Female 5500B9001 50 3.0 (77) 7.3 (185) 3.5 (1.6)
2½ Female 5500A9002 65 4.0 (102) 6.9 (173) 3.5 (1.6)
* NPT port threads. For BSPP threads, add a “D” prefix to the model number.
Pressure Range: 150 psig (10 bar) maximum.
MUFFL-AIR
®
Silencer
male threads illustrated
Female Pipe Threads
For ports 1¼ through 2½
Male Pipe Threads
For ports 1/8 through 1¼
• May be installed on all L-O-X
®
and manual L-O-X
®
with EEZ-ON
®
operation valves
with pressure sensing port
• Provides a means to verify the release of downstream pressure to next obstruction
Visual Pop-Up Indicator or Pressure Switch (electrical)
CLAMP for MODULE CONNECTIONS
Specially designed clamps provide a quick and easy assembly or disassembly of
MD3 modules. Two allen-head bolts quickly tighten or loosen the clamp using a
5/32 or 4mm hex key. The clamp contains a plate carrying two O-rings to provide
positive sealing between modules. Order clamp by part number R-A118-105.
Combined clamp and bracket (below) can be ordered by part number R-A118-105M.
MOUNTING BRACKET
Two brackets are normally used to mount an FRL to a vertical surface. The mounting
bracket attaches to the module-connecting clamp (see above) with a single screw.
Each bracket then employs two bolts (1/4” or 6mm) to connect the assembly to the
mounting surface. Order bracket and screw by part number R-A118-103. Combined
bracket and
clamp (above) can be ordered by part number R-A118-105M.
Mounting Bracket
Part No. R-A118-103
Module
Connecting Clamp
Part No. R-A118-105
Combined
Clamp & Bracket
Part No. R-A118-105M
A
B
A
B
Model Inlet Port Verification Dimensions inches (mm) Weight
Number Size* Option Length Width Depth lb (kg)
988A30 1/8 Pop-Up Indicator 0.98 (25) 0.55 (14) 0.55 (14) 0.03 (0.01)
586A86 1/8 Pressure Switch 4.3 (110) 2.01 (51) 1.22 (31) 0.28 (.12)
* NPT port threads.