Owner manual
www.rosscontrols.com 3
Modular L-O-X
®
Air Entry Packages
Air Entry Packages with Control Reliable
Energy Isolation
Model Air Entry Port Size C
V
Dimensions (inches/mm)
Number Type In-Out Exh. 1 to 2 2 to 3 Length Width Depth
Cat-2 with SV27 RC208-09 FR 1/2 1 6.3 9.2 14.80 (374.9) 11.00 (279.0) 6.60 (167.7)
Cat-2 with SV27 RC208L-09 FRL 1/2 1 6.3 9.2 14.80 (374.9) 11.00 (279.0) 6.60 (167.7)
Cat-3 with DM
1
Series E RC304-09 FR 1/4 1/2 1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-3 with DM
1
Series E RC306-09 FR 3/8 1/2 1.9 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-3 with DM
1
Series E RC304L-09 FRL 1/4 1/2 1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-3 with DM
1
Series E RC306L-09 FRL 3/8 1/2 1.9 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM
2®
Series E RC404-09 FR 1/4 1/2 1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM
2®
Series E RC406-09 FR 3/8 1/2 1.9 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM
2®
Series E RC404L-09 FRL 1/4 1/2 1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM
2®
Series E RC406L-09 FRL 3/8 1/2 1.9 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
* NPT port threads. Specify voltage and hertz when ordering.
Do not use in power press clutch/brake applications.
• Pre-engineered panel-mounted design with air entry via filter and
regulator “FR”, or filter, regulator, and lubricator “FRL”.
• Includes 3/2 Normally Closed Sensing Valve which senses poppet position
and state. Electrical feedback via DPST switch (double-pole, single-throw).
• Applications include Air Dump and Trapped-Pressure Release.
Air Entry Package with 3/2 Normally Closed
Sensing Valve
• Pre-engineered panel-mounted design with air entry via a filter and
regulator “FR”, or filter, regulator and lubricator “FRL”.
• Includes DM
2®
Series E Double Valve with Monitoring & Memory:
a) Self-contained dynamic monitoring system requires no further valve
monitoring controls.
b) Dynamic memory of abnormal function prevents unintentional reset with removal
of air or electricity.
• All necessary features for safety applications are included:
a) Electrical reset valve
b) Status indicator switch for valve condition (ready-to-run) feedback.
• Pre-engineered panel-mounted design with air entry
via a filter and regulator “FR”, or filter, regulator and
lubricator “FRL”.
• Includes DM
1
Series E Double Valve with Monitoring:
a) Self-contained dynamic monitoring system requires no further valve
monitoring controls.
b) Ready-to-run: If an abnormality clears itself upon the removal of electricity to both
solenoids, it will be ready-to-run again. It does not remember the abnormality & stay
in a locked-out state until intentionally reset. Therefore, cumulative abnormalities
may go undetected.
c) Status indicator switch for valve condition (ready-to-run) feedback.
Do not use in power press clutch/brake applications.